Designer Series LED Undercabinet Lighting
Models: SLTA-L09S and SLTA-L18S
FEATURES
Plug-in design for easy installation
Quick and easy linking system
Three lighting options - top, back or both
Control lights with Wave-on Technology
Ultra Low Profi le Design
INCLUDES
SLTA Series Plug-in Light Fixture (2-pack 9" Silver; 18" Silver)
(1) Power Supply, (1) Linking Cord, Mounting Hardware.
IMPORTANT SAFETY INSTRUCTIONS
For use with 120V, 60Hz electrical power supply only.
WARNING: TO PREVENT OVERHEATING AND ELECTRICAL SHOCK DO NOT INSTALL IN SMALL ENCLOSED SPACES. TO
PREVENT ELECTRICAL SHOCK DO NOT INSTALL IN WET LOCATIONS.
SAVE THESE INSTRUCTIONS
1. Read and understand all of these instructions before installing fi xture.
2. Keep these instructions in a safe place for future reference.
3. Do not mount over sink or stove.
4. WARNING: These products may represent a possible shock or fi re hazard if improperly installed or attached in any way.
Products should be installed in accordance with these instructions, current electrical codes and/or the current National
Electric Code (NEC).
SECTION 1 - PREPARATION FOR INSTALLATION
Tools Needed
Parts of this Light Fixture
-
Two 9" or one 18" light fi xture with Wave Sensor.
-
Linking Cord
-
Power Supply
-
Mounting Hardware (screws, screw plugs)
SECTION 2 - INSTALLATION
Placement of Fixture
Determine location for connecting to nearest 120V polarized receptacle. (Note: before
mounting to cabinet be sure fi xture is within 5' of an electrical outlet, considering path
cord will take to be neatly and securely mounted to cabinet and wall.) If you are not sure
about this installation consult a local licensed electrician or electrical contractor before
proceeding.
Locate Mounting Holes: Place fi xture on mounting surface and with a thin screwdriver,
pencil or scratch awl mark the spot where the screws will be located through the Mounting
Holes in the top of the fi xture. See Figure 2. Do the same for a multiple fi xture installation.
For mounting into drywall, drill 3/16" holes for the plastic wall anchors (not included). Insert
the plastic wall anchors into the proper holes and tap them into place so they are fl ush
with the surface of your drywall. For mounting into wood cabinets drill 1/16" pilot holes,
1/2" deep. Caution: Check your cabinet thickness fi rst. Be careful not to drill through
cabinet.
Prepare fi xture for installation by turning screws provided into mounting holes in the top of
the fi xture so they protrude through the back of the about an 1/8". This will help you line up
screws to mounting holes. Attach fi xture to cabinet or wall by tightening screws securely.
Insert screw plugs for a clean installation. Linking cords can only be attached in one
way as each connector has a different end. DO NOT FORCE CONNECTOR INTO SOCKET.
Connect 5' Power Cord to the Fixture as shown in Figure 3. Plug in Power Cord to a 15A
circuit grounded outlet. Warning: Do not conceal power supply cord inside a wall, ceiling,
soffi t, kitchen cabinet, or similar permanent structure. Do not run the power supply cord
through holes in walls, ceilings or fl oors.
Use UL listed cable staples (not included) to route Power Cord to bottom of cabinet and
wall for a clean installation.
INSTRUCTIONS FOR INSTALLATION OF
PLUG-IN LIGHTING FIXTURE
Interconnecting Multiple Fixtures
WARNING: In multiple fi xture installations do not electrify fi xture group until all electrical
connections have been made and fi xtures have been securely mounted. For the SLTA
Designer Series Undercabinet Light the maximum number of fi xtures that can be linked is
THREE. DO NOT EXCEED THIS QUANTITY.
SLTA Series fi xtures may be interconnected using the Linking Cord supplied with this kit.
Linking cords can only be attached in one way as each connector has a different end.
DO NOT FORCE CONNECTOR INTO SOCKET. See Figure 4.
Follow Fixture Installation instructions above. There should be some slack in the Linking Cord
so that the electrical connectors are not stressed in any way. Use cord clips (not included)
to keep cord safely attached to mounting surface. WARNING: Do not use Linking Cord as
a means to turn fi xtures on and off. Do not link other manufacturer's or other Westek brand
fi xtures to this fi xture.
Sensor
Step 1
Locate Holes
Step 2
Drill Pilot Holes
CET
Sensor

Publicidad

loading

Resumen de contenidos para WESTEK SLTA-L09S

  • Página 1 Use cord clips (not included) to keep cord safely attached to mounting surface. WARNING: Do not use Linking Cord as a means to turn fi xtures on and off. Do not link other manufacturer’s or other Westek brand fi xtures to this fi xture.
  • Página 2 Fixture Operation FCC Statement SLTA Series fixtures have 3 light configurations - Front Light on, Side Light on and Both Lights This equipment has been tested and found to comply with the limits for Part 15 of the FCC on. Wave hand below the Wave Sensor on the fixture to automatically turn light on/off. See rules.
  • Página 3 Câble de liaison utiliser le câble de liaison comme moyen d’activer et de désactiver les luminaires. Ne pas • Alimentation connecter de luminaires d’autres fabricants ou d’autres luminaires de marque Westek à • Matériel de montage (vis, bouchons à vis) ce luminaire.
  • Página 4 Instrucciones de Instalación para el Accesorio de Iluminación Enchufable Iluminación LED para debajo de gabinetes de la Serie Designer de WESTEK Modelos: SLTA-L09S y SLTA-L18S CARACTERÍSTICAS Diseño enchufable para facilitar la instalación Sistema de acoplamiento fácil y rápido Tres opciones de iluminación - superior, posterior o ambos Sensor Controle las luces con Tecnología de control por gesto de mano (Wave-on)

Este manual también es adecuado para:

Slta-l18s