ATX/ATX2-RX1-E-BF5-xx
ATX/ATX2-SX1-E-BF5-xx
1
2 3 4 5 6
0 Vdc
+Vcc
Code / D0
Data / D1
Clock
Terminal block Connector
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1)
for the main supply.
Main power supply:
Communication:
RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock & Data)
Protection:
IP66
When the reader is switched on, the orange LED and the buzzer are activated.
The operating mode for the Buzzer and LED can be programmed by a configuration card or controlled by the remote system with
a 0 Vdc respectively on the "Green", "Red" and "Buzzer" inputs of the reader's connector.
The initial status of the input « Switch » is memorized when the supply is turned on. If the status becomes different of the initial
status, the reader will detect the wrenching and:
- will be emitted the wrenching signal on the line "Data/Data1" for RX1 & SX1. This function is configurable via a configuration card.
- will do the operations configured with a configuration card (R / S X2 & X3).
Caution: switch on the reader when it is in its final position.
For Data signals, 10k pull-up resistors are connected internally to V
R & S readers are configurable with SCB configuration card created with SECard.
- If the SCB is compatible with reader's firmware, the LED lights green and buzzer beeps five times.
- If the SCB is not compatible with reader's firmware, LED lights red and buzzer is activated 1s.
- if the SCB key is different from the reader's key: no action.
More details about reader communication are available in the protocol specification (Spec_Protocole_5AB-7AB_V1.2_US.pdf).
ATEX & IECEX reader
Installation procedure
Hybrid ATX/ATX2 125kHz/13.56MHz
7 8 9 10
0 Vdc
Buzzer
+Vcc
Red
0 Vdc
Green
SW
Type RX1/SX1
(Wiegand)
1
2
3
Data 0 (D0)
4
Data 1 (D1)
5
Clock
6
7
8
9
10
Range +7 Vdc up to +28 Vdc
Available Baud rate
Factory Baud rate
© STid - 20 PA des Pradeaux FR13850 Gréasque – NI1104X03 - Page 4 sur 18 - Ed. 20/01/2021
Lecteur ATEX & IECEX
Notice d'installation
ATX/ATX2-RX2-E-BF5-5AB
ATX/ATX2-SX2-E-BF5-5AB
1
2 3 4 5 6
7 8 9 10
Buzzer
Red
Green
Tx
Rx
SW
Type RX1/SX1
(Clock & Data)
0 Vdc
+Vcc (+7 Vdc / +28 Vdc)
Code
Data
Clock
Switch
Green Led
Red Led
Buzzer
NC
Power Supply Characteristics
Typical: +12 Vdc
Characteristics
Buzzer / LED
Anti-Tearing (optional)
TTL Pull-ups
(power supply voltage).
in
Reader configuration
RS232/RS485 communication
9600, 19200, 38400, 57600, 115200 bauds
9600
ATEX & IECEX lectores
Manual de instalación
ATX/ATX2-RX3-E-BF5-7AB
ATX/ATX2-SX3-E-BF5-7AB
1
2 3 4 5 6
0 Vdc
+Vcc
0 Vdc
L +
L -
Type RX2/SX2
Type RX3/SX3
(RS232)
(RS485)
0 Vdc
0 Vdc
Tx
L +
Rx
L -
US
FR
ES
7 8 9 10
Buzzer
Red
Green
SW