1. CAUTIONS:
• Turn power off before inspection, installation, or removal.
• Risk of electric shock - Do not use where exposed to water or weather.
• Suitable for Damp Locations - The lamp is suitable for use in wet locations when used in an outdoor rated fixture.
• Do not open – no user serviceable parts inside.
• LED Retrofit lamps require 120V-277V input voltage.
• Not for use with dimmers.
• This device is not intended for use with emergency exit fixtures or emergency exit lights.
• This device complies with Part 15 of the FCC rules and has been tested and found to comply with the limits for a Class B digital device. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate
the equipment.
Item#
Minimum Fixture Dimensions
35162/35163/35164
11.42"x11.42"x11.42"(290x290x290mm)
35165/35181
11.02"x11.02"x11.02"(280x280x280mm)
35166
12.40"x12.40"x12.40"(315x315x315mm)
2. INSTRUCTION:
STEP 1: Disconnect power from the luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance.
STEP 2: Remove the existing lamp. Dispose of the lamps per local equirements.
STEP 3: Disconnect and remove the existing ballast, capacitor, and ignitor. Dispose of the components per local requirements.
STEP 4: Connect the Line wire (Line/Hot) to the center contact (eyelet) of the lamp holder.
STEP 5: Connect the Neutral wire (Common) to the shell of the lamp holder.
STEP 6: Insert and screw in the LED Retrofit lamp into the lamp holder.
STEP 7: Close the wiring compartment. Watch to be sure the wires are not pinched, bound, or crimped when closing the compartment.
STEP 8: Switch on the power.
3. WIRING DIAGRAMS:
L
N
Self Ballasted CFL Wiring Diagram
Ballast
L
Capacitor
N
HPS/HID Wiring Diagram
INSTALLATION AND SAFETY INSTRUCTIONS
Replacing Self Ballasted CFL Lamp
Self ballasted
CFL Lamp
Replacing HPS/HID Lamp
Ignitor
HPS / HID
lamp
Item#
Minimum Fixture Dimensions
35166
12.40"x12.40"x12.40"(315x315x315mm)
51540
15.75"x15.75"x15.75"(400x400x400mm)
35166
12.40"x12.40"x12.40"(315x315x315mm)
L
Replacing
N
with
LED Retrofit Lamp Wiring Diagram
L
Capacitor
Replacing
with
N
LED Retrofit Lamp Wiring Diagram
1
LED Retrofit
Lamp
Ballast
Ignitor
ESF-WH-021