. This tank is designed for operation on
ambient temperature water systems
limited
to
a
maximum
working
pressure of 125 PSI (PRO-XLB and
PRO-XLT series). If your system has
the ability to exceed the specified
working pressure, a suitable safety
device must be installed. This can be
either a high pressure electrical cut-off
switch and/or a pressure relief valve.
Failure to follow these instructions can
cause tank rupture or explosion and
result in property damage, serious
personal injury or death.
.Maximum
allowable
inlet
water
pressure is 125 PSI (PRO-XLB and
PRO-XLT series). For example if
daytime pressure is over 80 PSI,
nightime pressure may exceed the
maximum (this apply . Use a pressure
reducing valve to reduce the pressure
if necessary.
.A relief valve should be installed which
is set to open at excessive pressures.
The relief valve should be installed
close to the connection of the tank to
the system piping and have a
discharge equal to the pump´s
capacity .