NOTES
• The indicated noise value results from laboratory tests before the conditioner leaves
the factory.
• The nominal cooling and heating capacities have been tested under the conditions
described below :
Cooling
internal
Heating
internal
• The data above are subject to modifications without prior warning. The data on the
data sheet of your air conditioner are precise and updated.
• Range of operating temperatures :
Internal DB/WB ( °C)
External DB/WB ( °C)
• If the operating voltage of the air conditioner exceeds 230V 10%, it will malfunction.
• Each unit (internal/external) is provided with a wiring diagram of the conditioner.
• If the supply cable or connection cable is damaged, it must be replaced by the
manufacturer, its maintenance agent or a qualified technician in order to avoid any
danger.
112503-112511-new.indd 57
27°C(DB)
19°C(WB)
20°C(DB)
15°C(WB)
Cooling maxi-
Cooling minimum
mum
32/23
21/15
43/26
21/15
© FAR GROUP EUROPE
external
35°C(DB)
external
7°C(DB)
Heating maximum
Heating minimum
27/--
24/18
en
24°C(WB)
6°C(WB)
20/--
-5/-6
18/12/07 16:52:54