Installer Programming Menu; User Programming Menu - Risco RP128EPS000A Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installer Programming Menu

Function
Add/Delete
Power
Supply
Module:
Add/Delete
Utility
Output
Module:

User Programming Menu

Function
Overload
Restore
View
Trouble
Battery
Quick Key
Description
[7] [1] [4]
Selection of new type: PS02, followed by
selection of Bell/Speaker (if exists) and
assigning to partition.
[7] [1] [3]
New type: UO02
A Two-output relay module.
Quick Key
[2] [0] [2]
[3] [1]
[4] [CODE] [2]
SMPS - Installation Guide
Description
NOTE:
Performed only if Aux. output is overloaded and
then switched off, code is required and the
relevant SMPS is selected.
The Grand Master/Installer/Sub-
installer/Manager can use this option to
restore the Aux. power (If overload
condition is still present, disconnection of
all loads from AUX. output is required!).
Trouble messages dedicated to the SMPS:
Potential overload: The SMSP has
detected a potential current overload when
calculating the total expected current
consumption from the siren and the Aux.
outputs.
Overload: The total current consumption
from the Aux. and siren outputs exceed
3A.
Tests the standby battery of the pre-
selected SMPS. Battery voltage of the
relevant SMPS is displayed on the LCD.
13