CHANGING
BLOWER D ISCHARGE
(Optiona0
Theblower is shipped w ithitsdischarge facing DOWN. FoF
lowthese steps ONLY if:
o theposition oftheblower discharge needs t obemoved
soductwork does notinterfere withfloor j oists, plumb-
ingor wiring below.
® it isnecessary torotate t heblower discharge tothe
RIGHT o rLEFT.
Place theunit o nitsback ona table orwork surface.
CLAMP
NUTS
BLOWER
DOWN DISCHARGE o MOVING BLOWER LEFT OR R_GHT
1. Loosen the 4 nuts and 2 clamp channels.
2. Slide blower to desired position.
3. Use supplied cover plate to close open space (if any).
4. Tighten nuts to secure top of blower and use sheet metal
screws through bottom flange to secure bottom of blower.
BOTTOM
FLANGE
LEFT OR RIGHT DISCHARGE
1. Remove the 4 nuts and 2 clamp channels.
2. Carefully lift blower and disconnect motor plug if necessary.
Reposition blower and RECONNECT MOTOR PLUG.
3. Use supplied cover plate to close open space (if any).
4. Replace clamp channels and use nuts to secure the blower
in its new position.
5. Use sheet metal screws through bottom flange to secure
bottom of blower.