COMPRESSOR RUNS CONTINUOUSLY AND
SAFETY VALVE OPENS AS PRESSURE RISES
Defective pressure switch: Replace switch.
Defective safety valve: Replace safety valve
with genuine replacement part
EXCESSIVE
STARTING
(AUTO START)
Excessive condensation in tank: Drain more
often.
AIR LEAKING FROM RELEASE VALVE ON
PRESSURE SWITCH
Check valve stuck in an open position: Remove
and replace check valve.
18
AND
STOPPING
ESPECIFICACIONES TÉCNICAS
COMP325
VOLTAGE-FREQUENCY
TANK CAPACITY
MAX. VOLUME
MAX PRESSURE
NO LOAD SPEED
POWER
WEIGHT
COMP325K
VOLTAGE-FREQUENCY
TANK CAPACITY
MAX. VOLUME
MAX PRESSURE
NO LOAD SPEED
POWER
WEIGHT
127 V ~ 60 Hz
25 L
5,7 CFM
8 bar (116 PSI)
3 350 r/min
1,5 HP
20 kg (44 lb)
127 V ~ 60 Hz
25 L
5,7 CFM
8 bar (116 PSI)
3 350 r/min
1,5 HP