Batteries must not be disposed of with normal domestic waste. There will be a collection point near you!
Technical data
Display
Rated voltage range
Phase sequence indication
Indication
Frequency indication
Switchable load
Duty cycle
Nominal In current
Peak current Is
Phase test Pol
Protection class
Impedance
Continuity test
Climate category
Operating temperature
Protection class
Overvoltage category
Testing standard
Voltage supply
LC display with backlighting
3...1000 V AC (TRMS) +/- 3 digits
4...1400 V DC +/- 3 digits
Yes
0.85 Un
0, 16.66...500 Hz
30 mA at 230 V AC
30 s on \ 240 s off
< 3.5 mA
< 0.3 A, with buttons pressed (FI/RCD)
> 100 V AC
II
625 k for ELV AC
0.1...199.9 k
N Normal
-15 to +45 °C, at > 95% RH to +31 °C
IP 65
CAT IV 1000 V
EN 61243-3:2014
2x 1.5 V Type AAA Micro
18