ADI140857
Installation Instructions – M-32T, M-5MR, M-5P30 & M-5P36
Instructions d'installation – M-32T, M-5MR, M-5P30 & M-5P36
Instrucciones de instalación de las luminarias M-32T, M-5MR,
M-5P30 & M-5P36
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
WARNING
Read and understand these instructions before
installing fixture. To prevent electrical shock,
be sure power is turned off before installing or
servicing this fixture.
INSTALLATION
General Installation for All Modules
Lamp Modules can be installed into platforms before
●
●
installation into the ceiling or after the ceiling is
installed.
Remove cardboard overspray protector and
●
●
reinstall after Module installation to protect interior
of platform from paint and construction dirt.
Power connections are done via polarized three wire
●
●
quick connects. The three wire female connector
is located 1" above the frame next to the access
door. The access door may need to be removed
depending on which module is to be installed.
(Figure 1.)
Optical elements are keyed to provide proper
●
●
orientation of optics. A dropped finger will fit into
a notch on the reflector assembly to allow it to
pull tight to ceiling. If trim does not seat properly
against the ceiling, rotated it 180° and insert again.
(Figure 2.)
M-32T Compact Fluorescent 32W Triple Tube
Lamp Module
1.
Loosen thumbscrews holding access door,
remove door by lifting vertically to disengage from
thumbscrews. Remove access door from fixture.
2.
Insert M-32T access door with ballast mounted
to it through aperture. Position door to replace
original door. Slide door down vertically over
thumbscrews. This can be done without removing
thumbscrews from housing. Tighten thumbscrews
to firmly hold door into place. (Figure 1.)
3.
Plug Quick connect into platform receptacle.
N
otee:
Iris® recessed fixtures are designed to meet
the latest NEC requirements and are UL listed
and CSA certified. To assure full compliance with
local codes and regulations, check with your local
electrical inspector before installation.
4.
Socket is inserted into the top of the reflector and two
thumbscrews are tightened. Some reflectors allow for
two lamp positions- move socket into proper position
for optimal performance. See label on reflector for
proper location. (Figure 3.)
5.
Install reflector element and lamp. For best
performance use 4-pin compact fluorescent lamps all
by a single manufacturer.
M-5P30 Line Voltage Adjustable Accent Module
1.
Plug Quick Connect into platform receptacle.
2.
Install Adjustable Accent mechanism into ceiling
aperture. Ring is keyed into platform by aligning notch
in ring with dropped finger on platform. Three springs
on Adjustable Accent ring snap into notches. (Figure 4.)
3.
Install lamp, and then install reflector.
Figure 1.
Dropped
Finger
Align
Notch
Figure 2.
TM
INS #
Access Door
Three Wire Female
Connector
Wall Wash
Thumbscrew
Position
Downlight
Position
Figure 3.