Declaration Of Conformity; Inserting/Replacing The Battery; Initial Operation - Bosch PMD 10 Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
OBJ_BUCH-1380-004.book Page 15 Wednesday, April 20, 2011 10:12 AM

Declaration of Conformity

We declare under our sole responsibility that the product described under
"Technical Data" is in conformity with the following standards or standardization
documents: EN 61010-1:2010-10, EN 61326-1:2006-05,
EN 301489-3:2002-08, EN 301489-1:2008-04, EN 300330-1:2010-02,
EN 300330-2:2010-02 according to the provisions of the directives
2004/108/EC, 1999/5/EC.
Dr. Egbert Schneider
Senior Vice President
Engineering
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
Leinfelden, 01.04.2011
Assembly

Inserting/Replacing the Battery

Alkali-manganese batteries are recommended for the measuring tool.
To open the battery lid 3, slide it in the direction of the arrow away from the bat-
tery compartment. Insert the battery provided. When inserting, pay attention to
the correct polarity according to the representation on the inside of the battery
compartment.
The battery indicator e always indicates the current battery status:
Battery fully charged
Battery has 2/3 of its capacity or less
Battery has 1/3 of its capacity or less
Please change battery
If the measuring tool is not used for a long period of time, the battery must
be removed. The battery can corrode or discharge itself over long periods.
Operation
Protect the measuring tool against moisture and direct sun light.
Do not subject the measuring tool to extreme temperatures or variations
in temperature. In case of large variations in temperature, allow the
measuring tool to adjust to the ambient temperature before switching it
on. In case of extreme temperatures or variations in temperature, the accu-
racy of the measuring tool and the display indication can be impaired.
Use or operation of transmitting systems, such as WLAN, UMTS, radar,
transmitter masts or microwaves, in the close proximity can influence
the measuring function.

Initial Operation

Switching On and Off
Before switching the measuring tool on, make sure that the sensor area
11 is not moist. If required, dry the measuring tool using a soft cloth.
If the measuring tool was subject to an extreme temperature change,
allow it to adjust to the ambient temperature before switching on.
To switch on the measuring tool, press the On/Off button 5.
To switch off the measuring tool, press the On/Off button 5 again.
When no button on the measuring tool is pressed for approx. 5 minutes and
when no objects are detected, the measuring tool automatically switches off to
save the battery.
Bosch Power Tools
Dr. Eckerhard Strötgen
Head of Product
Certification
2 609 140 838 | (20.4.11)
English | 15