Unit connectors
Network connector - RJ45 Ethernet connector. Supports Power over Ethernet. Using shielded
cables is recommended.
Power connector - 2-pin connector block used for power input.
Function
Pin number
GND
1
DC Power
2
Audio in - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used
from a stereo signal).
Audio out - Audio output (line level) that can be connected to a public address (PA) system or an
active speaker with a built-in amplifier. A pair of headphones can also be attached. A stereo
connector must be used for the audio out.
microSD memory card slot - The microSD memory card can be used for local recording with
removable storage
SD card slot (microSD)
I/O terminal connector - Used in applications for e.g. motion
detection, event triggering, time lapse recording and alarm
notifications. In addition to an auxiliary power and a GND pin, it
provides the interface to:
•
1 digital output – For connecting external devices
such as relays and LEDs. Connected devices can be
activated by the VAPIX® Application Programming
Interface (API), by the output buttons on the Live
View page or by an Event Type. The output will show
as active (shown under System Options > Ports & Devices) if the alarm device is acti-
vated.
•
1 digital input – An alarm input for connecting devices that can toggle between an
open and closed circuit, for example: PIRs, door/window contacts, glass break
detectors, etc. When a signal is received the state changes and the input becomes
active (shown under System Options > Ports & Devices).
Description
Ground
Power input 8-28 V DC
AXIS P1353/P1354 Installation Guide
AXIS P1353: max 6.4 W
AXIS P1354: max 6.4 W
Pin 4
1
2
Pin 2
Pin 1
Pin 3