Regulation (EU) n° 517/2014 of 16/04/14 on fluorinated greenhouse gases and repealing Regulation (EC) n°
842/2006
Leak checks
1. Operators of equipment that contains fluorinated greenhouses gases in quantities of 5 tons of CO
and not contained in foams shall ensure that the equipment is checked for leaks.
2. For equipment that contains fluorinated greenhouse gases in quantities of 5 tons of CO2 equivalent or more, but of
less than 50 tons of CO
2
Picture of the equivalence CO
1.
Load in kg and Tons amounting CO
Load and Tons amounting CO
From 7 at 75 kg load = from 5 at 50 Tons
Do no release R32 coolant liquid into the atmosphere. This is a fluoride greenhouse effect gas covered by the
Kyoto agreement with a global warming potencial (GWP) = 675 - (see the European Community regulations
on fluoride greenhouse effect gases Regulation (EU) No 517/2014).
Concerning the Gas R32, 7.40kg amounting at 5 tons of CO
Training and certification
1. The operator of the relevant application shall ensure that the relevant personnel have obtained the necessary
certification, which implies appropriate knowledge of the applicable regulations and standards as well as the necessary
competence in emission prevention and recovery of fluorinated greenhouse gases and handling safety the relevant type
and size of equipment.
Record keeping
1. Operators of equipment which is required to be checked for leaks, shall establish and maintain records for each piece
of such equipment specifying the followinginformation:
a) The quantity and type of fluorinated greenhouse gases installed;
b) The quantities of fluorinated greenhouse gases added during installation, maintenance or servicing or due to leakage;
c) Whether the quantities of installed fluorinated greenhouse gases have been recycled or reclaimed, including the name
and address of the recycling or reclamation facility and, where applicable, the certificate number;
d) The quantity of fluorinated greenhouse gases recovered
e) The identity of the undertaking which installed, serviced, maintained and where applicable repaired or decommissioned
the equipment, including, where applicable, the number of its certificate;
f) The dates and results of the checks carried out;
g) If the equipment was decommissioned, the measures taken to recover and dispose of the fluorinated greenhouse
gases.
2. The operator shall keep the records for at least five years, undertakings carrying out the activities for operators shall
keep copies of the records for at least five years.
equivalent: at least every 12 months.
2
.
2
2
Frequency of test
Each year
, commitment to check each year.
2
1
, equivalent or more