Stenner ECON FP Serie Manual De Instalación Y Mantenimiento página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PRE-PROGRAMMING REQUIREMENTS
C. Calculate Metering Pump Output Requirement in Gallons per Day .
Maximum System Flow Rate (gpm) x Dosage (ppm) x 1440
Solution Strength % x 10,000 = Solution Strength ppm
*
D. Reference the chart below to confirm the selected pump's maximum output
slightly exceeds the pump output requirement calculated in C.
FP Pump (up to 80 psi/5.5 bar)
Item Number Prefix
E20PHF
E20PHG
E20PHH
USA and Canada 800.683.2378, International 904.641.1666
Solution Strength ppm
Pump Tube
Roller Assembly
F
G
H
=
*
Maximum Output (gpd)
White
Black
Black
continued
Metering Pump Output
Requirement (gpd)
4.5
16.0
30.0
Econ FP
13

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Econ fp e20phfEcon fp e20phgEcon fp e20phh

Tabla de contenido