Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

S-9602P-RP, S-9602-XP-RP
Operation & Maintenance Manual
Model Numbers
S-9602P-RP
Origins Tub/Shower System
S-9602-XP-RP
Origins Tub/Shower System with integral service
stops to allow water shutoff at valve for service
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations..
Refer to www.symmons.com/warranty for complete
warranty information.
Dimensions
A A
B B
C C
D D
F F
H H
I I
Origins
J J
K K
E E
M M
G G
N N
FLOOR
FLOOR
®
Specification
S-9602P-RP / S-9602-XP-RP
Tub/Shower system powered by the Temptrol
Balancing valve. Features adjustable stop screw to limit
handle turn, integral service stops to allow water shutoff at
valve for service (S-9602-XP-RP only), integrated diverter
control, 1 mode showerhead with easy to clean rubber
nozzles, non-diverter tub spout, and standard 2.5 gpm
(9.5 L/min) flow restrictor. Components made from metal
and nonmetallic materials plated in standard polished
chrome finish.
Compliance
-ASME A112.18.1/CSA B125.1
L L
Notes:
1) All dimensions measured from nominal rough-in (see F as reference).
2) Dimensions subject to change without notice.
Pressure
®
Measurements
A
6-3/8", 162 mm
B
3-1/2", 89 mm
C
2-7/8", 73 mm
Shower Valve Hole Size
D
Min. Ø 3", 76 mm
Max. Ø 4", 102 mm
E
Ref. 77", 1956 mm
Rough-in
F
2-3/8" ± 1/2", 60 mm ± 13 mm
G
Ref. 32", 813 mm
Male 1/2" NPT fitting must
H
protrude 4" from
finished wall
I
5-1/2", 140 mm
J
Ø 2-1/2", 64 mm
K
Ø 2-3/4", 70 mm
L
2-1/8", 54 mm
M
Ø 5-3/4", 146 mm
N
Ø 2-1/2", 64 mm

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Symmons Origins S-9602P-RP

  • Página 1 (9.5 L/min) flow restrictor. Components made from metal and nonmetallic materials plated in standard polished Limited Lifetime - to the original end purchaser in chrome finish. consumer/residential installations.. Refer to www.symmons.com/warranty for complete Compliance warranty information. -ASME A112.18.1/CSA B125.1 Dimensions Measurements 6-3/8", 162 mm...
  • Página 2: Parts Breakdown

    Parts Breakdown Replacement Parts Item Description Part Number Showerhead 4-141 Shower Arm & 300S Flange Handle RTS-061 Assembly Dome Cover T-19 Shower S-9600TS-TRM-KIT Escutcheon Kit Water Supply Diverter Control RTS-062 Handle COLD Water Supply Tub Spout Tools Required Adjustable wrench Notes: 1) Apply a bead of silicone around the perimeter of all shower Allen wrench (1/8")
  • Página 3 Installation Installation note: For valve body installation, please see valve body manual. 1) Install diverter handle or volume 2) Install shower escutcheon (G) to 3) Install dome cover (E) to valve by control handle (J) into shower shower valve. Secure with two turning clockwise.
  • Página 4: Troubleshooting Chart

    WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. ■ ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 ■ ■ ■ ■ Copyright © 2017 Symmons Industries, Inc. symmons.com gethelp@symmons.com ZV-3249 REV 0 111017...
  • Página 5: Especificación

    Limitada de por vida: para el comprador original del pro- ducto en instalaciones del consumidor/residenciales. Cumplimiento Visite www.symmons.com/warranty para obtener la información completa sobre la garantía. -ASME A112.18.1/CSA B125.1 Dimensiones Medidas 6-3/8", 162 mm...
  • Página 6: Desglose De Piezas

    Desglose de piezas Repuestos Artículo Descripción Número de pieza Cabezal de 4-141 ducha Brazo de la 300S ducha y brida Ensamblaje del RTS-061 del mago Cubierta del T-19 domo Juego de Chapetón para la S-9600TS-TRM-KIT ducha Suministro de agua CALIENTE Mango para el control del RTS-062...
  • Página 7: Instalación

    Instalación Nota: Para instalar el cuerpo de la válvula, vea el manual. 1) Instale el mango del desviador 2) Instale el chapetón de la ducha 3) Para instalar la cubierta del o el mango del regulador del (G) a la válvula de la ducha. Ajús- domo (E) a la válvula gire en sen- caudal (J) en el chapetón de la telo con dos tornillos (F).
  • Página 8: Funcionamiento (Control De Temperatura)

    ■ ■ ■ ■ Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621 ■ ■ ■ ■ Copyright © 2017 Symmons Industries, Inc. symmons.com gethelp@symmons.com ZV-3249 REV 0 111017...

Este manual también es adecuado para:

Origins s-9602-xp-rp

Tabla de contenido