Power Options - Honeywell T6 Pro Hydronic Serie Instrucciones De Instalación

Ocultar thumbs Ver también para T6 Pro Hydronic Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Power options

S
S
Y
Y
2
G
C
U
U
Insert R and C wires into
designated terminals for primary
AC power (C terminal is optional
if batteries are installed, but it is
recommended). Remove wires by
depressing the terminal tabs.
Setting Slider Tabs
Set R Slider Tab.
• Boiler, hot water valve circuit, or hot water
relay panel wires to R and W. If the same
transformer is providing common to power
the thermostat, wire the transformer
common to C and leave the R slider tab in
the up position (1 wire). If a transformer
that is not powering the heating equipment
is used to power the thermostat display,
set the R slider tab to the down position
(2 wires). Wire the heat circuit to R and W,
then wire the separate transformer to Rc
and C.
NOTE: Slider Tabs for U terminals should be
left in place for this thermostat model.
A
L/A
O/B
W
AUX
2
E
W
K
R
Rc
Insert AA batteries for primary or backup
power. Match the polarity of the batteries
with the + / – marks inside the battery
compartment.
UWP Mounting System
3
R/Rc slider tab

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Th6100af2004T6 pro hydronic

Tabla de contenido