Pet Alley
1. Remove the PCB from the sensor funnel.
2. Swing down the pet alley mirror (see Figure 2). This deletes all but the top row of the
detector zones.
Note: When using the pet alley mirror mount the detector at 1.6m height in order to main-
tain correct coverage with the upper detector zones. Pet immunity extends for 10m. Do not
use this facility in larger areas.
3. Refit the pcb to the sensor funnel .
Mount the back
The 714r is designed for mounting by any of the methods shown in Figure 3. The case
back contains a number of possible fixing holes, marked by mouldings in the plastic. Chose
two to suit the location you have selected, and drill them out carefull.
1. Hold the back in location and mark and drill 5mm fixing holes in the wall.
2. Secure the back to the wall with 16mm countersunk head screws and wall plugs.
3. Clip the body of the detector to the back.
Fitting a Wall Tamper
If you wish to fit a wall tamper:
1. Cut out the large circle indicated in the back of the case (see Figure 4).
Make sure that you remove enough material so that the head of the tamper switch can
pass freely through the back of the case.
2. Mark the position of this circle on the wall at the place where the case back will be fit-
ted.
11
EN