SAFETY INFORMATION
Continued
6. Keep all air openings in front and bottom of
heater clear and free of debris. This will insure
enough air for proper combustion.
7. If heater shuts off, do not relight until you
provide fresh, outside air. If heater keeps
shutting off, have it serviced.
8. Do not run heater
• where flammable liquids or vapors are used
or stored
• under dusty conditions
9. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
10. Do not use heater if any part has been under
water. Immediately call a qualified service
technician to inspect the room heater and to
replace any part of the control system and any
gas control which has been under water.
11. Turn off and let cool before servicing. Only
a qualified service person should service and
repair heater.
12. Operating heater above elevations of 4,500
feet (1,371 m) could cause pilot outage.
13. To prevent performance problems, do not use
propane/LP fuel tank of less than 100 lbs. (45 kg)
capacity.
14. Provide adequate clearances around air
openings.
LOCAL CODES
Install and use heater with care. Follow all lo-
cal codes. In the absence of local codes, use the
latest edition of National Fuel Gas Code, ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
4
Glass Panel
Figure 1 - Vent-Free Gas Heater
www.desatech.com
Heater Cabinet
Ignitor
Control Knob
(under door)
116292-01A