Second Section - FOR THE INSTALLER
Connection, starting-up of the appliance and troubleshooting must be carried out by trained and qualified
fitters.
Caution: indoor electric network as well as ambient where the appliance is installed, must strictly comply
with standards and safety regulations in force.
The Manufacturer cannot assume any responsibility for any damage to persons or property
deriving from the non-observance of the above-specified norms.
Place the appliance in the required position and
adjust the feet to level. Remove all protective
films and adhesive labels.

WATER CONNECTIONS

1) Connect the end of drain pipe "S" (fig.2 -
Drain pipe should have slump to allow the
matters drain; under floor drain pipes should
have a dia. of 80-100 mm.
2) Connect inlet pipe "E" (fig.2 - pag.14) to a
3/4" screwed Gas tap .
The National and Regional Standards existing
on the subject must be rigorously respected.

ELECTRICAL CONNECTION

pag.14) th the drainage shaft.
Before connecting the machine, check to make
sure the voltage outlet of the mains is the same
as the voltage specified on the data plate of the
machine. A main switch must be installed
between the mains and the machine. This safety
measure also requires that the minimum
distance between the switch contacts is at least
3 mm and the disconnection on all poles
according to EN 60204 (VDE 113).
Fuses on the main switch must be 16 A .
The mains must be wired to be able to handle
the current drawn by the machine.The system
must also be provided with a proper ground lead
in accordance with the existings norms. The
electric cable must be of the following type
H05VV-F.