Technical Data - Einhell Royal TP 1750 NIRO Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
Anleitung TP 1750-1950 Niro
GB
1. Items supplied
1 Fountain pump with BIOCELL filter element
1 Cascade fountain
1 Spout connection

2. Technical data

TP 1750 Niro
Mains connection
230 V ~ 50 Hz
Power input
Max. pumping rate
Max. delivery head
Immersion depth
Fountain height
TP 1950 Niro
Mains connection
230 V ~ 50 Hz
Power input
Max. pumping rate
Max. delivery head
Immersion depth
Fountain height
3. Pump design
High-performance, universal, submersible motor
pump for continuous duty in garden ponds.
Oil-free motor
Stator hermetically sealed in casting resin
Permanent magnet rotor runs in water
4. BIOCELL intake filter
The intake filter for the fountain pump works with a
BIOCELL filter insert. BIOCELL is a special material
for cleaning water by natural, biological means.
Whereas normal mechanical filters are able only to
trap particles of dirt such as plant remnants or dead
insects and the like, biological filtration actually
breaks down the dirt, including muddy materials. This
decomposition is performed by nitrifying bacteria.
BIOCELL, a porous material developed specially for
biological filtration, provides these bacteria with ideal
conditions for propagation. Toxic organic substances
are transformed inside the BIOCELL into natural
plant nutrients - a natural process that will make a
4
22.06.2005
13:58 Uhr
special contribution to your garden pond's biological
equilibrium.
5. Safety instructions
Electric shocks can be fatal. It is vital, therefore,
to observe the following instructions:
The pump is to be operated only from a properly
installed socket outlet with earthing contact.
50 W
Use of the pump in swimming pools, garden
ponds and fountains as well as within their zone
1750 l/h
of protection is permitted only if the electrical
2 m
wiring is installed in accordance with VDE 0700
Part 702 and Part 738: Earth-leakage circuit-
3 m
breaker (e.l.c.b.) with 30 mA or 10 mA leakage
1,1 m
current. Please ask your electrician.
Caution! Never use the pump when there are
people in the pool.
Pumps with a 3 m power cable are to be used
only inside buildings. Pumps with a 10 m power
cable (H05RN-F minimum) are compulsory for
68 W
outdoor use.
1950 l/h
Pull out the power plug before starting any
maintenance work.
2,3 m
If the pump cable or plug is ever damaged, the
3 m
cable is not to be repaired! In this case you must
stop using the pump.
1,25 m
Take special care not to allow aggressive liquids
or abrasive substances to run through the pump.
Never suspend the pump from the pressure line
or electric cable.
Protect the pump from freezing temperatures.
Take suitable measures to keep the pump away
from children.
It is prohibited to use cable systems, extension
cables, connection cables or adapters without an
earthing contact.
6. Putting into operation
It is imperative to observe the above safety
regulations when you put the pump into operation.
Place the pump on a horizontal surface higher than
the bottom of the pool (this will reduce excessive
soiling by sludge deposits).
Never use the pump outside the water.
Seite 4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tp 1950 niro41.724.4541.723.90

Tabla de contenido