AERMEC VED_I Serie Manual Tecnico página 52

Tabla de contenido

Publicidad

ACCESORIOS VED 530/740I
• RDA_V: Straight fitting with rectangular
flange for ducting.
In galvanised sheet steel
• RPA_V: Intake plenum with rectangular
flange for ducting.
In galvanised sheet steel
• PA_V: Intake plenum with circular flanges for
ducting.
In galvanised sheet steel, the flanges are in plas-
tic
• RPM_V: Flow plenum with rectangular flange
for ducting.
In galvanised sheet steel, internally isolated.
• PM_V: Flow plenum with circular flanges for
ducting
• PMZ: plenum con amortiguadores motorizados
(para más detalles consulte la tarjeta dedicada).
In galvanised sheet steel, internally isolated, the
flanges are in plastic
• KFV: Circular flange kit for intake/flow
plenum.
In plastic
• VCF4_C: Kit made up from motorised 3-way
valves with isolating shell, fittings and
isolated copper pipes. For main coils.
230V~50 Hz power supply
• VCF4_H: Kit made up from motorised 3-way
Mod. VED
RDA 450 V
RDA 670 V
RPA 450 V
RPA 670 V
PA 450 V
PA 670 V
RPM 450 V
RPM 670 V
PM 450 V
PM 670 V
PMZ
KFV
SW3
SIT 3
(1)
SIT 5
(2)
PXAE
WMT05
WMT06
WMT10
VCF45C
VCF45H
VCF47C
VCF47H
VCF25C
VCF25H
VMF-SIT3
(3)
VMF-E0
VMF-E1
VMF-SW
VMF-SW1
VMF-E4
VMF-E5B
VMF-E5N
(1)SIT3 Mandatory accessory on the VED units coupled to thermostats different to the VMF System
(2)SIT5 Allows to realise a network of VED units (max 3) controlled by a centralised PXAE panel
(3)Mandatory accessory for coupling with VMF-E0 or VMF-E1
IVEDITI 1405 - 4880950_00
52
valves, fittings and isolated copper pipes. For
heating only coils. 230V~50 Hz power
supply
• VCF2_C: Kit made up from motorised 2-way
valves, with fittings and isolated copper pipes.
For main coils. 230V~50 Hz power supply
• VCF2_H: Kit made up from motorised 2-way
valves, with fittings and copper pipes.
For heating only coils. 230V~50 Hz power supply
CONTROL PANELS
The complete features of the control panels are
described in the dedicated sheet.
Some control panels require coupling with other
a c c e s s o r i e s ,
documentation.
A C C E S S O R I E S T O C O U P L E W I T H T H E
CONTROL PANELS
• SIT3 : Thermostat interface board
Mandatory accessory on the VED units
coupled to thermostats different to the VMF
System
• SIT5: Thermostat interface board.
Allows to realise a network of VED units
(max 3) controlled by a centralised PXAE panel
• SW3: Water minimum temperature probe to use
Accessories compatibility
530
532
c o n s u l t
t h e
r e l a t i v e
540
541
with PXAE control panel.
VARIABLE MULTI FLOW SYSTEM
VMF System: The complete fittings of the VMF
System management system are described in
the dedicated sheet.
Some VMF components require coupling with
other accessories, consult the relative
documentation.
• VMF-SIT 3 : Thermostat Interface Board
VMF. Mandatory accessory on the VED unit sup-
plied with VMF-E0 / E1 thermostat.
730
732
740
741

Publicidad

Tabla de contenido
loading