Del ozone Eclipse EC-10 Manual De Instalación página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Open the Enclosure Door and locate the three mounting holes on
the back wall of the Enclosure. There will be two holes located
near the top on the left and right and one located in the center
near the bottom. Refer to Figure 1 for clarification.
2. Install screws (or other hardware appropriate for the mounting
surface) through the two mounting holes near the top of the
enclosure. Install the last screw through the mounting hole
near the bottom of the enclosure. Mounting hardware must be
driven until the head fully contacts the enclosure wall. Mounting
hardware head must not be smaller than 0.25 inches (6.3 mm) in
diameter and the threads of the hardware must be smaller than
0.25 inches (6.3 mm) in diameter.
2C. Electrical
2C-1. Main Power
This device is intended to be installed by a certified electrical
technician, in accordance with local electrical codes. Connect
the DEL Eclipse to the pool timing clock so that the DEL Eclipse
operates simultaneously with the pool pump. The DEL Eclipse has
three available Knockouts for a 1/2 inch conduit fitting, two on each
side and one on the back. Remove only the ideal Knockout and
install the proper conduit fitting. Open the Enclosure and locate the
Terminal Block. Connect Line 1, Line 2, and Ground to the Terminal
Block as indicated by the label on the inside of the enclosure
door. Refer to the IMPORTANT SAFETY INSTRUCTIONS at the
beginning of this manual for important wiring information.
2C-2. Earth Grounding Lug
Using an 6 AWG (13.3 mm
on the bottom of the DEL Eclipse, marked to an appropriate earth
contact.
2D. Plumbing
Ozone gas is introduced to the pool circulation line using a venturi
injector. Suction developed by the venturi allows the DEL Eclipse
generator to operate safely under vacuum.
Note: Water must not travel back to the ozone generator.
Mounting the unit above the water line and scheduled check valve
replacement will keep water from entering the DEL Eclipse.
Eclipse Installation & Operations Manual
) conductor, connect the Grounding lug
2
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Eclipse ec-20Eclipse ec-40Eclipse serieEc-10Ec-20Ec-40

Tabla de contenido