Reed Manufacturing UPC616A Manual Del Operador página 2

Cortatubos universales
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

l. sAFEtY instrUCtiOns & WArninG
ll. dEsCriPtiOn/CAPACitiEs
lll. AssEMblY
i. sAFEtY instrUCtiOns & WArninG
A. Always Comply With:
1. General Industry Safety & Health Regulations, issued by
OSHA.
2. ANSI Specification Nos. B186.1, B7.
3. State and Local Regulations.
b. Abbreviated Form of Above regulations:
These regulations are not all inclusive—study and com-
ply with all above regulations.
1. Check Cutter Speed Before Mounting Cutter.
2. Use Tachometer
Actual speed must not exceed rated speed.
3. Perform Speed Checks When:
a. A tool is issued for use.
b. After all tool repairs.
4. Use Tools Only For Intended Purpose
5. Test & Operate Tools at 90 PSIG Maximum
Only exception is if tool is marked otherwise.
6. Use Recommended Air Line Equipment
This includes air line filters, regulators, and lubricators.
7. Stop Immediately If:
a. Unusual sound is heard, or...
b. Unusual vibration is experienced (Refer to Section
III to check if proper assembly was followed).
8. Check Speed Rating Of Blade
Must equal or exceed speed rating of air motor.
9. Mount Blade According To Regulations. Refer to Section
IIIA - IIIB.
10. Inspect Blade
a. Refer to aforementioned regulations. (Section IA)
b. Discard if chipped, cracked or otherwise damaged.
11. Mount Proper Blade Guard
a. Refer to Section IIIC.
b. Sample Warning Label:
12. Always Wear Protective Equipment When Tool is in Use
2
— tAblE OF COntEnts —
lv. OPErAtiOn
2
v. MAintEnAnCE
2, 3
vl. rEPlACEMEnt PArts list
3, 4, 5
13. Employ a Safety Program
WArninG: Failure to comply with all safety
regulations may result in serious injury.
ii. dEsCriPtiOn
A. Pipe Cutter Model: UPC 616A, 616AP, 636A,
nOtE: Models UPC836APE and UPC848APE are
specifically for use on PE (high density polyethylene)
pipe. With a larger diameter blade (8" diameter), they
can cut up to 2.65" (69 mm) wall thickness PE pipe. they
can also be used on PVC plastic pipe when fitted with
a PvC blade. UPC836APE and UPC848APE do not come
with a pressurized water system and cannot be used on
pipe requiring a water-cooled blade such as Cast iron,
Pit Cast, ductile iron, Clay, or Concrete.
B. Motor Specifications:
a. Refer to aforementioned regulations (Section IA)
concerning goggles, face shields, and other
protective clothing.
b. Appropriate hearing protection which reduces noise
to acceptable levels must be worn.
Refer to ANSI and OSHA specifications for inspection
and maintenance procedures.
648A, 836APE & 848APE
Horsepower Generated by UPC = 1.7 H.P. (1.3 kW)
Maximum R.P.M. = 3675
Air Consumption = 50 cu. ft./min. (1.4 cu. m/min.)
Pressure = 90 P.S.I. Maximum (6 BAR)
Shut -Off =
3
/
" Ball valve
4
Air Supply Fittings =
/
" Dixon "Air King" Coupling
3
4
5, 6
6
7