Rotary SPO12 Standard 500 Instrucciones De Uso E Instalación página 9

Ocultar thumbs Ver también para SPO12 Standard 500:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8. Overhead: Install overhead assembly to Mounting
Bracket with (2) 3/8"-16NC x 3/4" Flanged HHCS, (2) 3/8-
16NC flanged locknut, Fig. 7c. Ensure limit switch box is
mounted on power unit side. Tighten bolts at center of
overhead assembly.
Fig. 7a
Fig. 7b
COVER NOT SHOWN
9. Power Unit: Put the (4) 5/16"-18NC x 1-1/2" flanged
locking HHCS thru holes in power unit bracket using Push-
Nuts to hold in place, Fig. 8a. Mount unit with motor up to
column bracket and install (2) 5/16" Flanged locking Nuts.
Install and hand tighten Branch Tee to pump until O-ring
is seated. Continue to tighten the locknut to 10-15 ft-lbs.,
or until the nut and washer bottom out against the pump
manifold. NOTE: You may still be able to rotate the Branch
Tee. This is acceptable unless there is seepage at the
O-ring. If so, slightly tighten the locknut.
CAUTION
Over tightening locknut may tear O-ring or
distort threads in pump manifold outlet.
10. Hoses: Clean adapters and hose. Inspect all threads
for damage and hose ends to be sure they are crimped,
Fig. 8b. Install hose and hose clamps, Fig. 9a & Fig. 9d.
Flared Fittings Tightening Procedure
1. Screw the fittings together finger tight. Then, using the
proper size wrench, rotate the fitting 2-1/2 hex flats.
IMPORTANT Flare seat MUST NOT rotate when
tightening. Only the nut should turn.
2. Back the fitting off one full turn.
3. Again tighten the fittings finger tight; then using a
wrench, rotate the fitting 2-1/2 hex flats. This will
complete the tightening procedure and develop a
pressure tight seal.
CAUTION
Overtightening will damage fitting resulting
in fluid leakage.
Use 3/8"-16NC x 3/4"
Flanged HHCS and
Flanged Locknuts
9
Fig. 7c

Publicidad

Tabla de contenido
loading

Tabla de contenido