A
3
1
4
2
5
4
B
Fig. 8: assembling the storage tank transfer set
A
to the following buffer tank, connection 12
B
to the leading buffer tank, connection 12
Completing the mixer
1. Attach the coupling.
Fig. 9: mixer with coupling
2. Screw the actuator drive to the mixer.
Fig. 10: mixer with actuator drive
3. Attach the rotary knob.
SOLVIS Speicherumladesatz SV-3 · Technische Änderungen vorbehalten 10.14 · P23-M
1 Installing the SV-3 Storage Tank Transfer Set EN
7
6
Fig. 11: mixer with actuator drive and rotary knob
The image shows the position for charging the leading
buffer tank.
Position the sensor S7 on the storage tank
1. Apply heat conducting paste to the sensor and insert
into the corresponding sensor sleeve (see
2. Fasten the sensor lines.
Fig. 12: Install the sensor
Connecting the electrical wires for the actuator drive
1. Blue N: "N" from output A20.
2. Black Y: „L" from output A24.
3. Brown L: "L" from output A20.
1.4 Start-Up
Filling the system
1. Fill the system according to the installation instructi-
ons for the storage tank (P20).
2. Perform a pressure test after you have filled the sys-
tem.
3. Attach the insulation shell.
4. Insulate the pipe lines and valves in accordance with
the German Energy Conservation regulations [EnEv].
Start up the system (see
in the operating instructions (P31)).
Fig. 7).
the "Start-Up" section
5