Technical parameters
Input
Input:
Max. frequency pulse
reading:
Outputs
Output (power supply
12 V for sensors):
Communication
Installation BUS:
Data transfer indication:
Power supply
Supply voltage / tolerance:
Dissipated power:
Rated current:
Rated current for full
load on output 12 V DC:
Connection
Terminal:
Operating conditions
Air humidity:
Operating temperature:
Storing temperature:
Protection degree:
Overvoltage category:
Pollution degree:
Operating position:
Installation:
Design:
Dimensions and weight
Dimensions:
Weight:
TECHNICAL SUPPORT | E-mail: support@inels.com | Mobil: +420 778 427 366 | Tel.: +420 573 514 276, +420 573 514 211 | Fax: +420 573 514 227 | www.inels.com
Made in Czech Republic
IM3-140M
14x NO or NC against GND (-),
IN1 - IN7 -are balanced inputs
20 Hz
12 V DC / 150 mA
BUS
green LED RUN
27 V DC, -20 / +10 %
max. 1 W
25 mA (at 27 V DC), from BUS
100 mA
max. 2.5 mm
2
2
/ 1.5 mm
with sleeve
max. 80 %
-20 .. +55 °C
-30 .. +70 °C
IP20 device, IP40 mounting in the switchboard
II.
2
any
into a switchboard rail to DIN EN 60715
3-MODULE
90 x 52 x 65 mm
104 g
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech republic | e-mail: elko@elkoep.com
Balanced input
Simple
Double
Warning
Before the device is installed and operated, read this instruction manual carefully and with full
understanding and Installation Guide System iNELS3. The instruction manual is designated for
mounting the device and for the user of such device. It has to be attached to electro-installation
documentation. The instruction manual can be also found on a web site www.inels.com. Attention,
danger of injury by electrical current! Mounting and connection can be done only by a professional
with an adequate electrical qualifi cation, and all has to be done while observing valid regulations.
Do not touch parts of the device that are energized. Danger of life-threat! While mounting,
servicing, executing any changes, and repairing it is essential to observe safety regulations, norms,
directives and special regulations for working with electrical equipment. Before you start working
with the device, it is essential to have all wires, connected parts, and terminals de-energized. This
instruction manual contains only general directions which need to be applied in a particular
installation. In the course of inspections and maintenance, always check (while de-energized) if
terminals are tightened.
ALARM
TAMPER
2k2
INx
GND
ALARM
TAMPER
1k1
1k1
INx
GND
2/2