TIMING LIGHT ___________________________________________________________________________
INDICATIVE VALUES
PLEX Electronic Ignition
Impeller output: with starting motor 0.9 ÷ 1.2 V; 1000 ÷ 4000 RPM 8 ÷ 22 V.
Electronic Ignition DIGIPLEX and MICROPLEX
Impeller RPM: Digiplex (pin 2
and pin 3) Microplex (pin 3
and pin 16)
with starting motor 4.5 V; 2000 RPM 1.8 ÷ 6 V; air cap 0.4 ÷ 1.3 mm.
Impeller PMS: Digiplex (pin 1
and pin 5) Microplex (pin 2
and pin 1)
with starting motor 4.5 V; 2000 RPM not lower then 8 V.
VISA LNA Ignition
Extract a little the connector but not completely with starting motor 6 ÷ 7 V.
Bosch Ignition 0227/100/025
Impeller output: with starting motor over 2 V; 2000 RPM over 16 V.
40
SERVICE MANUAL