Pump wintering:
Before turning off the system at the end of the season or for a long period, dose clean
water to rinse the tube, then place the roller-holder as shown in the figure, rotating it
clockwise.

TROUBLESHOOTING

1. The pump does not turn on:
- Check the power supply connection
2. The pump turns on but does not function:
- Check display and configuration: the pump could be disabled or an alarm is active
3. The pump works correctly but does not inject liquid into the plant:
- Check the level of product in the tank
- Check that the foot filter is not clogged
- Check that the injection valve is not clogged
- Check the suction and head valves
4. Liquid leakages from pump body:
- Check that the tubes are well inserted and the nuts well tightened
- Check that the pressure at the injection point is not too high
- Remove the transparent protection cover and check the integrity of the internal tube
EF110_r1.0 – 10/2019
Set the pump for continuous operation (P4 = 1), but stop it with the ON/OFF key.
Insert the left fitting onto the new tube, in its place, while paying attention that the
rounded part is positioned inwards.
Then turn the roller-holder clockwise, so that the tube is inserted in its seat.
Insert the right fitting in its seat and secure the transparent cover by screwing the
two front screws.
Connect the suction and injection tubes, then set correctly the parameter P4.