Installing LP Gas Tank

To operate, you will need one precision-filled standard grill LP gas
tank with external valve threads .
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
outdoor fire table.
Inserting LP Gas Tank
W WARNING: Make sure LP gas tank valve is closed.
1 .
Open door .
2 .
Loosen LP gas tank retainer bolt by turning counter-clockwise .
3 .
Place precision-filled LP gas tank upright into hole in outdoor fire table base so the tank
valve is facing the gas line connection .
4 .
Secure tank by turning LP gas tank retainer bolt clockwise until tight .
5 .
Close door .
Connecting LP Gas Tank
1 .
Before connecting, be sure there is no debris caught in the
head of the LP gas tank, head of the regulator valve or in the
head of the burner or burner ports .
2 .
Connect regulator/hose assembly to tank by turning knob
clockwise until it stops .
Disconnecting LP Gas Tank
1 .
Before disconnecting, make sure the LP gas tank valve is
"CLOSED ."
2 .
Disconnect regulator/hose assembly from LP gas tank by
turning knob counterclockwise until it is loose .
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving
this grill.
3 .
Place the protective cap cover on the LP tank and store the
tank outdoors in a well ventilated area out of direct sunlight .
BlueRhino.com
Available in U.S. only.

Operating Instructions

Checking for Leaks
W WARNING: Before using this outdoor
20 lb
fire table, make sure you have
9 Kg
read, understand and are following
all information provided in the
"Important Safeguards" section
12.2 in. / 31 cm
on page 2. Failure to follow those
instructions can cause death, serious
injury or property damage.
Burner Connections
1 .
Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank .
2 .
Visually check the connection between the
burner/venturi tube and orifice .
3 .
Make sure the burner/venturi tube fits over the
orifice .
W WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury or damage to
property.
4 .
Please refer to diagram for proper installation
(Figures 1 and 2) .
5 .
If the burner/venturi tube does not rest flush
to the orifice, as shown, please contact
1 .800 .762 .1142 for assistance .
Tank/Gas Line Connection
1 .
Make 2-3 oz . of leak detection solution by
mixing one part liquid dishwashing soap with
three parts water .
2 .
Make sure control knobs are in the " OFF"
position (Figure 3) .
3 .
Connect LP gas tank per "Installing LP Gas
Tank" section .
4 .
Turn LP gas tank valve to "OPEN ."
5 .
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1 and 2) .
a . If any bubbles appear, turn LP gas tank valve
to "CLOSED," reconnect and re-test .
b . If you continue to see bubbles after
several attempts, turn LP gas tank valve to
"CLOSED" and disconnect LP gas tank, per
"Disconnecting LP Gas Tank" section . Contact
1 .800 .762 .1142 for assistance .
c . If no bubbles appear after one minute, turn
LP gas tank valve to "CLOSED," wipe away
solution and proceed .
Lighting
W WARNING: NEVER light the burner
with the cover on the outdoor fire
table.
W CAUTION: Keep outdoor gas
appliance area clear and free from
combustible materials, gasoline and
other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of
combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
1 .
Make sure all labels, packaging and protective films have been removed from the outdoor
fire table .
2 .
Check for obstructions of airflow to the burner . Spiders, insects and webs can clog the
burner/venturi tube . A clogged burner tube can lead to a fire .
3 .
Control knob must be in the " OFF" position (Figure 3) .
4 .
Clear small area of glass rocks away from the igniter cover (Figure 4) .
5 .
Connect LP gas tank per "Installing LP Gas Tank" section .
6 .
Turn LP gas tank valve to "OPEN ."
7 .
Push and turn control knob to (HIGH) . The burner should light . If it does not, repeat up to
three times .
8 .
After 20 seconds, release and turn control knob counterclockwise to adjust flame to
desired height .
9 .
If ignition does not occur in 5 seconds, turn burner control knob to " OFF," wait
5 minutes, fan with a newspaper or magazine, and repeat lighting procedure .
Replacement Parts
1.800.762.1142
Figure 1
LP Gas
Connection
Figure 2
X
X
X
Figure 3
OFF / ARRÊT
Figure 4
Figure 5
7
LP Gas Valve
with Orifice
X
X
11.8 in. – 19.7 in.
30 – 50 cm