7.4 Pulse output function module

The module is equipped with 2 pulse outputs, which can be freely pro-
grammed using the IZAR@SET software. The outputs are indicated as
"O1 - " and "O2 - " on the terminal strip and as Out1 and Out2 in the
display.
ƒ
external supply:
Vcc = 3-30 VDC
ƒ
output current ≤ 20mA
with a residual voltage of
≤ 0.5V
ƒ
open collector (drain)
ƒ
electrically insulated
ƒ
Output 1: f ≤ 4 Hz
pulse width: 100 - 150 ms
pulse duration:
125 ms ± 10 %
pulse pause:
≥ 125 ms – 10 %
ƒ
Output 2: f ≤ 100 Hz
pulse duration/pulse
pause~1:1
ƒ
The volume pulse weight-
ing can be freely pro-
grammed
ƒ
standard: last digit in the
display