DESCRIPTION
Single-phase control panel for roll-up doors. Compatible with Vario radio transmitters.
Inputs protected by zener diode. Protection of main feed and motor with fuse 6A. LED indicator. Alternative button and
safety contact input.
INSTALLATION
Be sure mains are disconnected before proceeding with the installation.

DESCRIPTION OF TERMINALS

Power:
1. Supply 230V ac -
2. Supply 230V ac -
3. Closing motor -
4. Opening motor -
5. Common motor -
6. Power supply +12 VDC -
7. Power Supply -12 VDC
OPERATION
8. Safety contact
9. Common motor
10. P. Alt. Alternative button (N.O.)
N.C. Normally closed – N.O. Normally open
OPERATION
You can start the operation by means of a transmitter or an alternative button. The operation ends due to the following
conditions: activation of door limit switches or end of operating time. The door limit switches do not have connection with
the control panel. The operating time is programmable up to a maximum of 2 minutes and 30 seconds, considering this a
safety time.
In addition, the automatic closing time is programmable up to a maximum of 3 minutes and it adjusts the waiting time befo-
re executing automatically the closing operation. The alternative button and the transmitter accomplish the same function.
If the door is opening, when we press the transmitter button or the alternative one, it stops, if we press it again it closes, if we
press it again it stops and if we press it one more time it closes again, and so on.
OPTIONS SELECTION
Select
I1
Timer / Auto closing
ON timed automatic closing. OFF Automatic closing off.
Timer
I2
programming
ON programming operation time (I1 OFF). Programming closing time (I1 ON).
OFF time programming disabled.
Radio
I3
programming
ON radio programming for new transmitters enabled. OFF radio programming disabled
Dead
I4
Man
ON For closing operation press and hold the alternative button or the transmitter otherwise the movement stops. OFF
Normal operation.
Programming automatic closing time
It can be carried out only if the door is in rest position. First, place the switch I1 and I2 to ON, then the programming starts by
pressing the start button or a previously programmed transmitter and ends by pressing again the start button or a transmit-
ter.
The time between the two impulses will be set. A buzz and a light will indicate the beginning and end of programming.
Programming operating time
It can be done only after you close the door with the start button or a previously programmed transmitter. Once you set
the program with the switch I2 to ON and I1 to OFF, the programming starts by pressing the start button or a previously
programmed transmitter. A buzz and a light signal indicate the beginning of the programming and the door will open up to
the corresponding limit. Once opened, we give the closing command by pressing the start button or the transmitter until the
door reaches the limit of closure, moment in which a buzz and a light will indicate the end of programming. At the operating
time, a margin of 3 seconds must be added before stopping in order to ensure full operation of the door.