The device must be provided with an electrically dissipative connection to earth
during operation in Group IIC (Group A) gas environments. This can be achie-
ved by using the device handheld, or by mounting the device in the approved
accessories. An alternate dissipative connection to earth must be provided when
operating the device in Group IIC (Group A) gas environments without any contact
to the user or accessories.
• When using the monopod accessory, the user shall maintain contact with the
metallic pole to provide electrical dissipation. Do not hold the monopod using
the rubber ball only.
• Do not attempt to service or dismantle the Cube 800. Opening, dismantling
or attempting to service the Cube 800 will void any warranty and hazardous
location ratings. The safety of the device needs to be tested after repairs are
implemented. Repairs are to be conducted by Librestream Technologies Inc. or
by personnel or service centers authorized by Librestream Technologies Inc.
only. For repair center information contact support@ecom-ex.com.
This CAUTION symbol appears within the manuals and on the product label.
The CAUTION logo is used to draw attention to important safety critical mat-
ters. When this symbol appears on the product label, consult accompanying
documents for more information.
3. Faults and damage
If there is any reason to suspect that the safety of the unit has been impaired, it
must be withdrawn from use and removed immediately from the Ex-area.
We recommend that the unit is returned to the manufacturer for the inspection.
The safety of the device may be compromised, if, for example:
• there is visible damage to the housing
• the unit has been subjected to excessive loads
• the unit has been improperly stored.
• the unit has been damaged in transit.
• unit markings or inscriptions are illegible
• malfunctions occur
• permitted limit values have been exceeded
5