The 969 Quick Stop/Smart Stop can also
store 80 standard frames identified only by
their length and width dimensions.
The standard frame menu is accessed either
via the Main menu or via the Execution menu.
There are 10 pages of 8 standard sizes. All the
dimensions can be reprogrammed using the
numeric keypad.
A frame is executed by touching its key: the execution screen will appear, allowing only the
length and width values of the standard frame to be adjusted.
This allows standard frames to be combined with the SMART STOP measuring function or a
stored file.
All the values can be modified. There is no need to switch off the power for the new values to
be acknowledged.
RESET MEASURER : Press the measurer button and this key simultaneously to reset the meas-
urer origin, if it is incorrectly set.
STANDARD PLAY: Type the play value allowance you wish to add automatically for internal
dimension positioning, e.g. 1.5 mm.
Stop mechanical offset: Dimension at which the automatic stop is initialised each time the
power is switched on and the EXECUTE key is touched for the first time. This dimension can
be checked by cutting a moulding at 45° and measuring its thickness without rebate. If
necessary this dimension can be adjusted each time a stop or coder is removed. In this case,
check that the stop initialises approximately 2-3 cm beyond the proximity detector of the origin
take-up area.
LOCK EXT. SIZE : Type the value '1' if you do not wish the operator to be able to work with
external dimensions (the INTER/EXTER keys will be disabled).
To release, type the value '0'.
Pin code: Reserved for maintenance.
STANDARD SIZES:
MENU MAINTENANCE
PARAMETERS
In the main menu, touch
MAINTENANCE to access the parameters
page.