Safety instructions
WARNING
Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may
damage seriously the interface and/or the AC indoor unit.
• This interface must be installed by accredited technical personnel (electrician, installer or authorized technical personnel) and
following all the safety instructions.
• This interface must only be installed in a restricted access location.
• Before manipulating the AC indoor unit be sure it is completely disconnected from Mains power.
• In case of installation of the interface inside the AC indoor unit, fix the interface and communication cables preferably to any
appropriate point of the plastic cover of the unit taking care of no blocking free movement of mobile parts and as far as possible
from tubes containing liquids and power cables.
Installation instructions
1. Unplug the Air conditioner (AC) unit from the power supply line.
2. Access to the main Printed Circuit Board. *
3. Locate the socket connector marked as CN105. **
4. Select a location for the IntesisBox device.
5. Connect the A-end (the long one) of the supplied cable to the Air Conditioner CN105 connector and the B-end (the short
one) to the device AC connector.
6. Close the Air Conditioner unit.
7. Plug the AC to the power supply line. If connection with the Air Conditioner has been successful, IntesisBox device LED will
start blinking Green and then will change to steady Green.
* See Mitsubishi Electric installation or service manual for detailed information.
** In some old units, the CN92 connector is the one to be used, instead of the CN105.
IMPORTANT: Use only the cable attached. Extending or shortening the connecting cable included with the interface may cause it to
malfunction. Keep the connecting cable as far away as possible from electrical wires and ground wire. Do not bundle them together.
The User's Manual is available at:
https://www.intesisbox.com/intesis/product/media/intesisbox_me-ac-wmp-1_user_manual_en.pdf
Order code: IBWMPMIT001I000
Doc. Rev 1.3
La información en este documento puede variar sin previo aviso. / This information is subject to change without notice.
© Intesis Software S.L.U. - Todos los derechos reservados/ All rights reserved
IntesisBox es una marca registrada de / is a registred trademark of Intesis Software SLU
Installation Manual
URL
http://www.intesisbox.com
email
info@intesisbox.com
Phone
+34 938047134
1 / 2

Publicidad

loading

Resumen de contenidos para IntesisBox ME-AC-WMP-1

  • Página 1 AC connector. 6. Close the Air Conditioner unit. 7. Plug the AC to the power supply line. If connection with the Air Conditioner has been successful, IntesisBox device LED will start blinking Green and then will change to steady Green.
  • Página 2 6. Cierre la unidad de Aire Acondicionado. 7. Conecte el AC a la alimentación. Si la conexión con el Aire Acondicionado has sido exitosa, el LED del dispositivo IntesisBox empezará a parpadear en verde y posteriormente cambiará a verde fijo.