2-2 Mounting positions and image view area
◇ Wide picture
Approx.
1,050 mm
(3' 5")
◇ Zoom picture
Approx. 700 mm (2' 3")
Approx. 900 mm (3')
◆ The zoom position can be changed.
(Refer to the master station's operation manual.)
The factory setting is "Center " for Zoom mode.
2-3 cable
1
PVC jacket with PE (polyethylene) insulated cable is
recommended.
2
Never use individual conductors, twisted pair cable or coaxial
cable.
2-4 Wiring distance
D
JK-DA
JK-DV
JK-DVF
JK-DA
JK-DV
JK-DVF
◆ Objects appear smaller due
to greater distortion in the
surrounding sections compared
to the central section, but a
wider area is displayed.
The display range is a rough
estimation and may change
due to the installation
environment.
M
2
4
JK-1HD
JK-1MED
JK-1MD
A
2
JK-1MED
JK-1MD
A
◇ Wide picture
Up/Down
Mounting position
1,500 mm (5')
Approx. 2,000 mm
Approx. 1,800 mm
(6' 7")
Unit center
Approx. 1,050 mm (3' 5")
Approx. 950 mm
1,500 mm (5')
(3' 2")
500 mm (20")
Left/Right
◆ An area over a range of approx. 170° in a 500
Approx. 170°
mm radius from the camera displays.
(The display range is a rough estimation
500 mm (20")
and may change due to the installation
environment.)
◇ Zoom picture
(when mounting position is 1,500 mm (5'))
Up/Down
Zoom <Up>
Approx. 2,250 mm
(7' 5")
Approx. 1,850 mm
(6' 1")
Approx. 850 mm (2'9")
Unit center
Approx. 700 mm
Approx. 1,400 mm
(4' 7")
Approx. 1,150 mm
(3' 9")
1,500 mm (5')
500 mm (20")
Left/Right
Zoom <Left>
500 mm (20")
Approx.
Approx. 100 mm (4")
1,300 mm (4' 3")
JK-DA
JK-DV
JK-DVF
S
JK-1SD
Ø 0.65 mm
A
50 m
- 3 -
Mounting position
1,300 mm (4' 3")
(5' 11")
Approx. 1,050 mm (3' 5")
Unit center
Approx. 750 mm
1,300 mm (4' 3")
(2' 5")
500 mm (20")
Zoom <Center>
Zoom <Down>
Approx. 1,600 mm
(5' 4")
Unit center
(2' 3")
Approx. 850 mm
(2' 9")
1,500 mm (5')
Approx. 750 mm
500 mm (20")
(2'5")
Zoom <Center>
Zoom <Right>
500 mm
500 mm (20")
(20")
Approx.
Approx. 900 mm (3')
1,300 mm (4' 3")
2
JK-1MED
22 AWG
Ø 1.0 mm
165'
100 m
500 mm (20")
Unit center
1,500 mm (5')
Approx. 100 mm (4")
JK-1MD
18 AWG
330'

Publicidad