Operating Instructions
Four-indent crimping tool DigiCrimp® with digital display and wear monitoring
NOTE
An E... error message instead of the default setting of 1.0 mm or 2.0 mm shown in the display
after calibration means that the lower reference value has not been set correctly. You will need to
repeat calibration.
10 . E1 message after calibration or recalibration
If the crimper display shows an E1 message after several calibration or recalibration attempts (the message
will be shown in sequence at first, then permanently as E1), then the dies in your four-indent crimper are
so worn that the wear can no longer be compensated for. Send your crimper to the manufacturer or an
authorised repair shop for inspections.
11. Monitoring wear – General
Any tool is subject to a certain amount of wear, even if used properly. Press the MODE button (6) for ten
seconds – range: 8 to 15s – for your crimper's current condition with numerical data on the crimper display
(5).
The following information will be shown in sequence:
•
Serial number (eight digits in sequence)
•
Remaining lifetime in percent (remaining service life)
•
Reference value – lower setting as specified by the manufacturer
•
Number of calibrations so far
12. Troubleshooting and remedy
Display
Cause
The crimper was not turned down to its lower
E1
(reference) setting using the adjustment wheel
after changing the battery.
Rev.: 2016-06-10
Solution
Repeat the procedure (See 9, Calibration after
a battery change).
EN
9 / 10