Installation:
1. It is recommandable to mount the Temp probe
(the stainless steel cylinder) on a suitable
place, preferably +/- 1 meter above the fl oor.
2. Mount the TechGrow Clima Control Plus to the
wall with the supplied mounting kit or to a
DIN-rail.
3. Connect the sensor(s) to the right side of the
Clima Control Plus with the supplied (UTP-)
cable(s).
4. Plug the fan into one of the outlets of the Clima
Control Plus.
5. Plug the Clima Control Plus into an outlet.
6. Ready!
Connecting the controllers and sensors
All of the TechGrow Pro Series controllers and
sensors (except for the Temp probe) are
connectable to each other to guarantee an
optimal climate. It is possible to connect the
controllers to each other, so that you can control
your entire climate with merely the use of ONE
TechGrow S-4 sensor.
Since each device has 3 UTP connectors it is also
possible to connect for example, a Datalogger
DL-1 and/or an AM-T sms Notifi er.
Make sure that the controller is disabled before
you connect the sensor(s) to prevent any
disruptions. The sensor can be plugged into any
UTP connector.
Which sensors can be connected to the
Clima Control Plus?
The minimal sensor required is a Temp/RH. If you
wish to see the CO2 value in the display, simply
replace with a S-4 sensor.
The S-4 measures CO2-, temperature-, and
humidity values and detects light simultaneously.
Connecting extra sensors or other
devices
The Clima Control Plus can measure, display
and register min/max values of connected CO2-,
humidity-, and temperature sensors.
However, the Clima Control Plus "only" controls
the temperature.
If you wish to connect another sensor to the Clima
Control Plus, fi rst switch off the controller, wait a
few seconds and then connect the sensor. Plug
the controller back into the outlet.
ATTENTION: NEVER connect two of the
same type of sensors to your controller!!
For example: a Temp probe can never be
connected with an S-4 or a Temp/RH sensor
simultaneously
Automatic functions of the
TechGrow Clima Control Plus:
If there are no sensors connected to the Clima
Control Plus the following will appear on the
display: **NO TMP, RH or CO2 SENSOR**.
The backlight of the display will turn off
automatically after 60 seconds of no activity.
Only when the Push & Turn Button (PTB) is
pushed or turned, the backlight will turn on again.
Operating the Clima Control Plus:
The Clima Control controls the temperature in
your growing area.
While the temperature exceeds the set +
hysteresis, the fan power will slowly increase.
While the temperature is below the temperature
set, the fan power will slowly decrease.
While the temperature is below the temperature
set – hys and the fan power is at box-min, the
heater will be activated.
If the temperature exceeds the alarm temperature,
the alarm contact will be activated.
If the measured temperature in the room lies
between setpoint + hysteresis and setpoint - hys-
teresis, the LED will turn green to indicate that the
desired temperature is reached
Meaning of the LED
•
Light detected: light indicator (under the PTB).
•
FAN: indicates that the fan is being
controlled.
•
OK: indicates that the temperature lies
between set+hys and set-hys..
•
HEAT: indicates the temperature is below
set-hys, and the heater is activated.
9