CONSIDERATIONS FOR INSTALLATION

· The installation and testing operations must be performed solely by qualified per
sonnel in order to guarantee the proper and safe operation of the automatic gate.
· The company declines any responsibility for damage caused by incorrect
installations due to incompetence and/or negligence.
· Before assembling the automatism, check that the gate is in perfect working
order, hangs well on its hinges and is suitably lubricated. It must also comply
with the safety standards in force in the country of installation..
1- Before fastening the brackets provided, establish the coordinates using the data
given in Table 1, bearing in mind that they are valid if the operator is at maximum
extension minus one centimetre of the available stroke (CD) when the gate is
closed to obtain maximum working efficiency.
2- Data B in the table, with reference to the single values A, are to be considered as
values (recommended).
3- To anchor the piston, use the fastening brackets provided.
COORDINATES AND TABLE
1- Establish coordinates A + B
that are to be used.
2- Note: The stroke used (CU)
of the operator must never be
equal or greater than the
available stroke (CD)
3- The sum of coordinates A + B,
establishes the stroke used CU .
TABLE 1
Opening angle
90° Available stroke = 400mm
(without limitswitch)
90° Available stroke = 500mm
(without limitswitch)
Note1: A+B = CU (Stroke used)

INSTALLATION

A
B
A
160
175
185
200
250
CD = (Available stroke MAX) = 400/500mm
B
A
B
160
175
185
200
250
C
D
Cu
320
350
370
400
500