Technical Specifications

Model Number
Horsepower Rating
Voltage Rating
Frequency
Power Consumption
Response Time
Reset Time
Motor Type
Alarm Contact Rating
Over/Under Voltage Time-out
Operating Temperature Range
Note:
Pumptec is not designed for use on permanent split capacitor
(PSC) motors.
Dry well protection occurs when pump suction is broken. Deadhead
conditions may not always be detected due to variation in pump
load characteristics

Installation Instructions

1. Remove the cover from the Pumptec.
2. If you will be running a 1.5 hp motor, move the circuit board jumper
to the 1.5 hp position as shown in Figure 1.
5800020610
1/3 to 1.5
115 V/230 V
50/60 Hz
4W
3 Seconds
2 to 120 min.
Single-Phase Induction Run
1 Amp 115 V/230 V
2 minutes
-15 ºF to 130 ºF
1/3 hp – 1 hp Setting
(Factory default)
1.5 hp
Setting
Figure 1: Circuit board jumper
for 1.5 hp motors