If EVENING/MORNING is selected, Programming Menu 5 allows choosing the
MORNING timing behaviour, and Programming Menu 4 allows choosing the EVENING
timing behaviour.
Mind that the load output is switched off as soon as the battery has reached the
Low Voltage Disconnect threshold. The Low Voltage Disconnect has priority above
the nightlight function.
"Mid of night" is detected automatically as the middle between dusk and dawn,
no real time setting is required. It may take some days until the controller has
"learnt" midnight. This method can cause some inaccuracy but avoids any clock
readjustment. The controller's "Mid of night" can be different from the real time
midnight depending on your location.
The controller recognizes day and night based on the solar array open circuit
voltage. In Programming Menu 6 this day/night threshold can be modified
according to the requirements of the local conditions and the solar array used.
Threshold setting range
7.7/15.4V
Switching point Night>day
Switching point day>Night
4.9/9.8V
(Factory-
setting)
1.0/2.0V
Curve of open-circuit voltage solar array
35