General safety precautions
This installation manual is intended for professionally competent
personnel only. Read the instructions carefully before beginning
to install the product. Incorrect installation may be a source of danger.
Packaging materials (plastic, polystyrene, etc.) must not be allowed to
litter the environment and must be kept out of the reach of children for
whom they may be a source of danger. Before beginning the installation
check that the product is in perfect condition. For repairs or replacements
of product only original spare parts must be used. These instruction must
be kept and forwarded to all possible future user of the system.

1. Technical data

Degree of protection
IP43
Temperature
-20° C / +55° C
2. Installation
Properly fasten the COME function selector close to the automation.
NOTE: the COME function selector can be wall recessed on circular
boxes, not supplied.
3. Electrical connections
Carry out the electrical connections as shown in fig. 2.
NOTE: use shielded cable for the electrical connections.
WARNING: in accordance with Directive 2004/108/EC, the supplied
ferrites must be installed as shown.
-
Pass the cable through the ferrite, make 1 turn and protect it from
knocks by using heat-shrink sheathing or similar.
The ferrite must be secured to the cable near the terminal boards
(approximately 50 mm).
-
Two COME function selectors can be connected to one single automa-
tion, as shown in fig. 3.
-
With one single COME function selector the same function modes
can be set in two different automations, by carrying out the electrical
connections shown in fig. 4.
-
One or two COME function selectors can be connected in order to set
the same function modes up to a maximum of four different automa-
tions (not redundant type), as shown in fig. 5.
NOTE: for control panel networking, use the shielded cable (not supplied)
for data transmission, up to 1000 m total maximum length.
When COME function selector manages more than two automations, cut
the resistor
in the intermediate control panels (fig. 5).
X
-
The outlet connecting the automation to the personal computer,
through the DMCS software, can be accessed by removing the se-
lector cover (fig. 1). In order to monitor and operate the automation
via personal computer, follow the instructions in the DMCS software
operating handbook.
WARNING: if MD1 display modules are used, each MD1 display
module must be configured separately with each control panel
before connecting to the network.
It is sufficient to supply each control panel for at least 30 seconds with
its MD1 display module, then turn off the supply, connect to the network
and power all control panels simultaneously.
3.1 Commands
Command
1
OP
The closing of the contact opens the automation when the
COME functions selector switch is in any operating mode.
NOTE: if the operating mode selected is stop, the OPEN
command starts the delayed night-time closure sequence.
The opening of the contact deactivates the functions selector
1
KEY
switch.
WARNING: if an N.C. command is used, remove the jumper [P].
RESET
Pressing the key eliminates the code set in the functions
selector switch.
Description
3.2 Settings
OFF
Delayed night locking.
J1
60-second bi-directional sequence.
Emergency opening.
If the OPEN button is held pressed,
the COME function selector is set in
J2
the open door mode.
NOTE: if the function mode selected
is stop, the OPEN command triggers
the delayed night locking.
J3
Access code disabled.
J4
DMCS jack disabled.
3.3 Signals
LED
LED off
The COME function selector is working and no access code is set.
LED on
The COME function selector is protected by an access code.
The COME function selector is disabled.
LED flashing
Setting or elimination of access code in progress.
Start during the network acquisition phase (for 30 s).
The COME function selector or another automation are not re-
cognized by the network (switch off and start again repeating the
learning phase).
3.4 TELRC infrared beam receiver
Remote adjustment of the control panel settings can be carried out via
the TEL2 radio remote control, by installing the TELRC receiver inside
the COME function selector as shown in the TELRC receiver handbook.
4. Operation
After having connected the COME function selector and the control panels,
turn on all control panels together and wait 30 s.
During the initial learning phase the
green leds light up depending on the number of control panels networked.
If there are two COME function selectors networked the 6 green led
lights up.
Operating modes are shown in the table.
All the rights concerning this material are the exclusive property of Entrematic
Group AB. Although the contents of this publication have been drawn up with the
greatest care, Entrematic Group AB cannot be held responsible in any way for
any damage caused by mistakes or omissions in this publication.
We reserve the right to make changes without prior notice. Copying, scanning
and changing in any way are expressly forbidden unless authorised in writing by
Entrematic Group AB.
6
ON
Delayed night locking.
10-second bi-directional sequence.
Standard opening.
Impulse OPEN command.
Access code enabled.
DMCS jack enabled.
Description
key red led flashes and the 1-2-3-4