8] FAUlT FINDING

PROBlEM
Door
The lock is not receiving
locking
DC current.
impossible
The lock and the armature are
not lined up with each other.
Holding
force
reduced
Low voltage or armature
jammed.
Faulty
reed
Voltage too low. Misalignment.
switch
* Optional. Sold separately.
POSSIBlE CAUSE
SOlUTION
- Check that the wires are connected to the right
terminals.
- Check that the power supply is compatible.
- Check that the lock is connected to the circuit
correctly.
- Check that the lock is connected to the circuit
correctly.
- Check that the electromagnet and the armature
are properly aligned.
- Check that the contact faces are free from dirt and rust.
- Check that the armature is soft mounted.
- Check that the lock is receiving the correct power
supply satisfactorily.
- check the tightening of the armature
and the condition of the rubber.
- Check the power supply.
- Cable cross section to be determined according
to the power supply and the locking.
- e.g.: 2 x 1.5mm2 ≥ 10m.
EN
Electromagnetic lock
9