GiBiDi BE24-115V Instrucciones Para La Instalación página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

16
UK
5 - ELECTRICAL CONNECTIONS: CONNECTORS
FASTON
CF1
CF2
6 - ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
2
M1
3
4
5
6
7
8
M2
9
10
11
12
13
M3
14
15
16
17
18
19
20
M4
21
22
23
24
25
26
M5
27
28
M6
29
0 VAC from transformer
24 VAC from transformer
Signal
Description
M1+
Motor 1+
M1-
Motor 1-
M2+
Motor 2+
Motor 2-
M2-
+
Electric lock power supply
EL+
- Electric lock power supply 12V
EL-
+ FLASHLIGHT power supply 24 VDC MAX 10W.
LAMP/SPIA
- FLASHLIGHT power supply 24 VDC MAX 10W.
LAMP/SPIA
+24Vdc
External accessory power supply
+ACC
External accessory power supply common
-ACC
Motor 1 ENCODER +5VDC power supply.
5V
Motor 1 ENCODER signal.
S1
Motor 1 ENCODER power and signal common.
COM
Motor 2 ENCODER +5VDC power supply.
5V
Motor 2 ENCODER signal.
S2
Motor 2 ENCODER power and signal common.
COM
START input (N.O.).
START
PEDESTRIAN input (N.O.) (DIP 2_7)
PED
PHOTOCELL 1 input (N.C.). Input active only during closing. It stops and inverts the
motion, opening the gate completely. If the gate is closed, it does not affect its
PHOTO 1
functioning. If intercepted during pause, it reloads the pause time.
PHOTOCELL 2 input (N.C.). Input active during both opening and closing.
PHOTO 2
If intercepted, it immediately stops the motion and holds it stopped until the photocell
is freed. Upon release, motion always restarts in opening. If intercepted during pause, it
reloads the pause time.
STOP
Programmable 8K2 INPUT (STOP 8K2 – EDGE 8K2).
SAFETY
COM
Accessory common.
Accessory common.
COM
IN1
Unused imput.
IN2
Unused imput.
Antenna braid input.
COM
Antenna signal input.
ANT
+BAT
+Battery 24V MAX 3Ah.
-BAT
-Battery 24V MAX 3Ah.
Description
12V
MAX 10W
BE24

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

As05870/115v

Tabla de contenido