SLOT PARAM.
Definition
Close
Command re-
close
mapping
2ch Radio
Command re-
2ch
mapping
* only on CLONIX UNI AC U-LINK 230.
8) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
The use of some models causes lowered radio capacity. Adjust the system using an appropriate antenna tuned to 433MHxz.
8.1) COMPATIBLE U-LINK BOARDS
The CLONIX UNI AC U-LINK 230 lets you manage up to 3 u-link modules from amongst those listed below to activate relays with commands from
the PC via u-service or u-base 2, etc. or from android mobile devices via blue-entry, u-base2 mobile, etc. These commands can also be carried on
units appropriated connected via 485 board setting the input/slot features on the display.
BOARD
Module that manages Bluetooth communications with the host (PC or mobile) via U-link protocol.
B EBA BLUE
It manages every type of U-link protocol command.
This module is terminated on the specific U-link connector on the board.
Module that manages RS485 communications with the U-link host (PC).
B EBA GATEWAY 485
It manages every type of U-link protocol command.
This module is terminated on the specific U-link connector on the board.
Module that can be integrated in a Z-Wave network; it converts Z-Wave commands in U-Link protocol open, close and stop commands.
B EBA Z-WAVE
It only manages U-link protocol open, close and stop commands.
This module is terminated on the specific U-link connector on the board.
Module that permits communications via Bluetooth with a smartphone complete with the BlueEntry App. It converts
commands from the smartphone in open/start commands.
B EBA ANDROID
It only manages U-link protocol open and start commands.
This module is terminated on the specific U-link connector on the board.
Module that can read and save 1 codes from "Wiegand26" devices.
B EBA WIE
It only manages U-link protocol open, close, stop, start, pedestrian and 2ch radio commands.
This module is terminated on the specific U-link connector on the board.
Hardware converter module that only adapts hardware for RS485 network connections. It does not process transmitted data.
B EBA U-LINK 485
This module is terminated on the specific U-link connector on the board.
8.2) CONFIGURATION EXAMPLES Fig. E
Set 1 or Set 2 are two equivalent ways of setting the Receiver.
EXAMPLE 1
The command that arrives as modules is run by clonix according to the
mapping set by the operator.
You do not require the presence of all three modules. Each module can
be placed in one of the three slots. The configuration is done according
to the slot the module is inserted in. "
Beba Android in slot 1 sends a start/open command that is run in clonix
sending a command to output 1.
Beba Blue in slot 2 sends a with instruction to address 000 which is run
in clonix.
B EBA WIE in slot 3 sends a start command that is run in clonix sending
a command to output 2.
B EBA WIE in slot 3 sends an open command that is run in clonix sending
a command to output 1.
EXAMPLE 2
The command that arrives as modules is run by clonix according to the
mapping set by the operator.
Beba WIE in slot 1 sends a start command that is run in clonix sending
a command to output 2.
Beba Android in slot 2 sends a start command that is send crossing slot
3 to the address 2 unit.
The start command is run in the address 2 unit.
Each command that arrives in slot 2 is run in the unit with address
equal to the remote ID set in the slot properties.
EXAMPLE 3
The command that arrives as modules is run by clonix according to the
mapping set by the operator.
Beba Android in slot 1 sends a start command that is run in clonix sending
a command to output 2.
Beba Blue in slot 2 sends an instruction including address [xxx] (see u-
18 -
CLONIX U-LINK
INSTALLATION MANUAL
Cross out
Default
setting used
The Close command received via U-LINK protocol does not activate any output
0
The Close command received via U-LINK protocol activates output OUT 1
1
2
The Close command received via U-LINK protocol activates output OUT 2
2
The Close command received via U-LINK protocol activates output OUT 3*
3 *
The 2ch radio command received via U-LINK protocol does not activate any output
0
The 2ch radio command received via U-LINK protocol activates output OUT 1
1
1
The 2ch radio command received via U-LINK protocol activates output OUT 2
2
The 2ch radio command received via U-LINK protocol activates output OUT 3*
3 *
Description
OPERATION
service manual).
the instruction is carried across the Beba u-link 485 board to the
network to the system with matching address.
example:
u-service start instruction [000_nviOn_003 1.1]
It will be run in the unit with address 003.
The instruction address is not changed.
EXAMPLE 4
The command that arrives as modules is run by clonix according to the
mapping set by the operator
Beba Android in slot 1 sends a start command that is send crossing slot
3 to the address 3 unit.
The start command is run in the address 3 unit.
Each command that arrives in slot 1 is run in the unit with address
equal to the remote ID set in the slot properties.
Beba gateWay 485 in slot 2 sends an instruction including address [xxx]
(see u-service manual).
the instruction is carried across the Beba u-link 485 board to the
network to the system with matching address.
example:
u-service open instruction [000_nviOn_002 1.1]
it will be run in the unit with address 002.
The instruction address is not changed.
NB1 Beba gateway 485 and Beba Uniblue modules must have the
Address Type property of the slot where it is inserted equal to 0 to
operate correctly.
The Ubase2 program can also be used for board diagnostics with
Beba gateway 485 and Beba Blue modules.
NB2 Two modules of this type may not be simultaneously installed for
correct clonix U-link operations:
B EBA gATEWAY 485
B EBA BLUE
or Beba Blue and Beba gateway 485 may not be installed
together.