Troubleshooting
6-4-2 Troubleshooting Deflection Block
■ Countermeasures by Deflection Types
1. The screen is blank and only the relay repeats close and open when turning the power on.
▶ This happens when the vertical voltage or vertical signal is not supplied, and because the Micom operates for 5 to 10
seconds and then turns the power off by force as it cannot detect the vertical signal.
2. CHECK POINT
- Check that the vertical output voltage is measured in the FBT terminal.
→ VCC (+) : +16.5V
VCC (-) : -16.5V
▶ If you cannot measure the output voltage, check that the collector voltage of the horizontal TR is 1360V.
If the voltage is measured, the problem is a defect in the FBT unit.
(When you don't have an oscilloscope, and you can hear the high-voltage sound, you can determine that the horizontal TR
is normal.)
- Is the vertical input waveform output from the VCTI VDP Pin.
6-10