Specifications
Model
VT1, VT1/12
US Public Health
3
2 gpm (7.5 lpm) (0.45 m
/hr)
2
16mJ/cm
VIQUA Standard 30
3
1 gpm (4 lpm) (0.24 m
/hr)
2
mJ/cm
2
3
NSF/EPA 40mJ/cm
0.5 gpm (2 lpm) (0.12 m
/hr)
Length
20.3 cm (8")
Cell Diameter
6.5 cm (2.5")
Combo 1/2" MNPT/3/8"
Inlet/Outlet Port Size
FNPT
Shipping Weight
1.8 kg (4 lbs)
100-130V/
Voltage
12VDC
50-60Hz
Power Consumption
13 W
13 W
Lamp Watts
9 W
9 W
Maximum Operating Pressure
8.62 bar (125 psi)
Ambient Water Temperature
2-40 ºC (36-104 ºF)
Sterilume™-EX
Lamp Type
(standard-output)
Visual "Power-On"
Yes
Visual Lamp
Yes
Chamber Material
304 SS
1
Flow rates based on UVT
=95%
10
Units ending in "/MEX" meet the requirements established in the Mexican Official Norm NOM-244-SSA1-2008
VT1/2, VT1/2A,
VT4, VT4/12
VT1/2B
3
3
2 gpm (7.5 lpm) (0.45 m
/hr)
6.5 gpm (24 lpm) (1.4 m
/hr)
3
3
1 gpm (4 lpm) (0.24 m
/hr)
3.5 gpm (13 lpm) (0.8 m
/hr)
3
3
0.5 gpm (2 lpm) (0.12 m
/hr)
2.5 gpm (9 lpm) (0.6 m
/hr)
20.3 cm (8")
32 cm (12.6")
6.5 cm (2.5")
6.5 cm (2.5")
Combo 1/2" MNPT/3/8"
1/2" MNPT
FNPT
1.8 kg (4 lbs)
2.9 kg (6.5 lbs)
100-130V/
200-250V/50-60Hz
12VDC
50-60Hz
13 W
19 W
19 W
9 W
15 W
15 W
8.62 bar (125 psi)
8.62 bar (125 psi)
2-40 ºC (36-104 ºF)
2-40 ºC (36-104 ºF)
Sterilume™-EX
Sterilume™-EX
(standard-output)
(standard-output)
Yes
Yes
Yes
Yes
304 SS
304 SS
Specifications
Información general
Sección 2
VT4/2, VT4/2A, VT4/2B
3
6.5 gpm (24 lpm) (1.4 m
/hr)
3
3.5 gpm (13 lpm) (0.8 m
/hr)
3
2.5 gpm (9 lpm) (0.6 m
/hr)
32 cm (12.6")
6.5 cm (2.5")
1/2" MNPT
2.9 kg (6.5 lbs)
200-250V/50-60Hz
19 W
15 W
8.62 bar (125 psi)
2-40 ºC (36-104 ºF)
Sterilume™-EX
(standard-output)
Yes
Yes
304 SS
Elemento
Vainas tubulares de cuarzo fusionado GE 214
1
de extremo abierto con extremos pulidos al
fuego
2
Junta tórica
Lámparas UV Sterilume
3
para una larga vida coherente (9000 horas)
4
Tuerca de retención
5
Conector de lámpara
6
Controlador
7
Controlador (solo en los modelos de 12 VDC)
8
Abrazaderas de montaje de 6,35 cm
9
Base de conector de lámpara
10
Muelle
12
33
Información general
6
5
4
3
2
1
9
10
4
Figura 1 Componentes del sistema
Descripción
N.º pieza
QS-212
VT1, VT1/2, VT1/2A, VT1/2B, VT1/12, VT1/12/MEX
QS-330
VT4, VT4/2, VT4/2A, VT4/2B, VT4/12, VT4/12/MEX
410867
Se utiliza en todos los sistemas
S212RL
VT1, VT1/2, VT1/2A, VT1/2B, VT1/12, VT1/12/MEX
®
-EX de cristal duro
S330RL
VT4, VT4/2, VT4/2A, VT4/2B, VT4/12, VT4/12/MEX
RN-001
Se utiliza en todos los sistemas
-
-
BA-VT - Norteamérica
VT1 y VT4
BA-VT/2 - Europa
VT1/2 y VT4/2
BA-VT/2A -
VT1/2A y VT4/2A
Australia/Nueva Zelanda
BA-VT/2B - Reino Unido
VT1/2B y VT4/2B
BA-RO/P/12
VT1/12, VT4/12, VT1/12/MEX y VT4/12/MEX
410958-R
Se utiliza en todos los sistemas
270276-R
Se utiliza en todos los sistemas
SP008
Se utiliza en todos los sistemas
7
8
Sistemas UV

Publicidad

Tabla de contenido