Electrical connection
2.6
Connect one end of the power cable to the rear socket of the stove, and the other to the wall socket.
The voltage supplied by the system must match that specified on the stove dataplate and in the technical data
section of this manual.
During stove idle periods it is advisable to remove the power cable.
- Make sure the electrical system is equipped with an earth and differential switch in accordance with the
current Regulations.
-The power cable must never touch the stove exhaust pipe.
Wiring diagram
2.7
DHW BOILER
THERMOSTAT/FLOWSWITCH
PRESSURE
TRANSDUCER
NTC
probe
room probe
suppl.
thermostat
fume
probe
Wiring diagram for zone system
2.8
Before installing the heating stove in the house, check the type of heating system;
in case of several zones, a special electronic controller for multi-zone circuits, available as an optional, must be
installed. This is to prevent overheating of the heating chamber due to possible simultaneous closing of the zone
valves and consequent stopping of hot water flow.
Plumbing connections
2.9
The heating capacity of the unit must be previously established by calculating the building's heat requirement
according to current regulations. The system must be provided with all the components for correct and regular
operation; in fact according to the rules of proper workmanship in installation, shutoff valves and non-return valves
allowing the stove to be isolated in case of maintenance and/or checks, must be interposed between the stove and
the heating system.
Proceed slowly during heating chamber water filling, to allow correct and complete evacuation of the air from the
vent.
The pellet stove has an internal heating water circuit complete with circulating pump, safety valves, air vent,
temperature probes and pressure transducer.
If the heating system is managed in zones a multi-zone controller, available on request, must be installed.
PLC additional
accessories and consol
AIR FLOW METER
IGNITER
AUGER
Fume verifier encoder
BOARD L023
FUME EXTRACTION
PUMP
FAN
45
BOARD 1055
EARTH
3 WAY
VALVE
ALT= Heating chamber safety thermostat
ALD= Low pressure gauge
ALP= Pellet compartment safety thermostat
TERMO-VIOLA