Exiting time regulation

3.1.1
The exiting time allows the system user to leave the protected zones after the system
enabling. During this time a possible activation of the sensors of the all protection zones
doesn't activate alarms.
This timing is adjustable from 5 to 75 seconds by the trimmer situated inside of the central
unit, near the terminal boards.
The exiting time is signalled by the blinking of the green LED "USCITA" situated on the
front panel of the central unit.
Alarm time regulation
3.1.2
The alarm time is adjustable from 180 seconds to 3 ÷ 10 minutes by the trimmer situated
inside of the central unit, near the terminal boards.
Entering time regulation
3.1.3
In-put time is the time user needs to enter into protected places and to switch off the
system before alarm start. During this time, a possible activation of the sensors on the secured
zone,(zone 1) won't cause alarms.
This timing is adjustable from 5 to 90 sec through the trimmer in the control unit, next to
terminal box.
If the electronic key or any command system are installed out of the protected places is
advisable to regulate to the minimum this timing.
3.2
Exclusion of Internal buzzer
On the circuit of the control unit there is a jumper J1 (TM500P, TM900P, PROTEC9).
J1=OFF
TM500P
TM900P
PROTEC9
Alarm
NO
C
NC
Sound signals of the internal buzzer are excluded. (during out/in time and in
alarm condition)
J1
J1 OFF=BUZZER OFF
J1 ON=BUZZER ON
+
+
+
Sir
S.A.
12Vcc
Int12V
EXIT TIME
ALARM
J1
EXIT
BUZZER
+
G
R
Com
Key
Led key
zones 24H Z1
ENTRY TIME
ALARM
ENTRY
Z2
Z3 Z4 Z5 Z6 Z7 Z8
Programmation
27

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Protec serieTm400pTm500pTm900pProtec4Protec9

Tabla de contenido