The fl ow rate of water into the heater must not exceed 17,000 litres per
hour (3,740 UK gallons/hour) A higher fl ow rate will require the installation
of a bypass to prevent damage to the heater elements. The heater will not
operate unless the following minimum fl ow rates are achieved ie:
1,000 litres / hour (220 UK gallons/hour) for 3 ~ 6-kW heaters and
4,000 litres / hour (880 UK gallons/hour) for 9 ~ 15-kW heaters.

Water Quality

The water quality must be within the following limits:
PH 6.8 - 8.0
TA (Total alkalinity) 80—140ppm (parts per million)
Chloride Content MAX: 150 mg/litre
Free Chlorine: 2.0 mg/litre
Total Bromine: Max 4.5 mg/litre
TDS (Total Dissolved Solids) / Calcium hardness 200— 1,000ppm
Water chemistry is complicated if in doubt seek expert advise.
Operating Your Heater
Upon completion of the installation, run the water-circulating pump to
purge the system & heater of air (i.e. Remove any trapped air in the
system & heater). TIP: You can encourage air out of the heater fl ow tube by
gently elevating the exit port of the heater when the pump is running.
On initial power up of the heater the amber light should illuminate.
The heater will only switch 'On' (red light indicator illuminated) and the
amber light switching 'Off ' when the following criteria are met ie:
Water circulating pump is 'On' delivering in excess of the minimum fl ow
rate of water (see fl ow requirement information)
Water temperature set point (required temperature) is set to a higher
value than that of the water.