pro.Bose.com
Configuration example 4
REMOTE 1 and REMOTE 2 can be a volume control user interface accessory (PC 041966). In this configuration, REMOTE
1 controls the level of output one and REMOTE 2 controls the level for output two. A/B source selection for both outputs
is simultaneously controlled by the front panel switch. This configuration requires setting the REMOTE 1 CONTROL DIP
switch to ZONE 1 and the A/B SELECT DIP switch to FRONT.
Bose
1
PWR
volume
control
2
VOL
IZA 2120-HZ
Configuration example 5
REMOTE 1 can be a volume control user interface accessory (PC 041966). In this configuration, REMOTE 1 controls
the level of both outputs simultaneously. A/B source selection for both outputs is simultaneously controlled by the front
panel switch. This configuration requires setting the REMOTE 1 CONTROL DIP switch to ZONE 1+2 and the A/B SELECT
DIP switch to FRONT.
Bose
1
PWR
volume
control
2
VOL
IZA 2120-HZ
Remote connections to zone amplifiers
Remote volume control
The zone amplifiers are designed to work with the Bose
REMOTE connector on the rear panel of the amplifier is labeled to match the connector on the user interface. Use the
included 2-pin Euroblock. See the Bose volume control user interface accessory install guide for more details.
Bose
volume
1
PWR
control
2
VOL
ZA 2120-LZ/HZ
REMOTE 1
DIP switch settings
DIP switch settings
REMOTE 1
®
volume control user interface accessory (PC 041966). The
REMOTE 1
Making Connections
Bose
1
PWR
volume
control
2
VOL
IZA 2120-HZ
REMOTE 2
English - 31